Treatment of polluted air stream using a pilot scale biofilter
- سال انتشار: 1397
- محل انتشار: پنجمین کنگره دانشجویی پژوهشی منطقه جنوب غرب کشور
- کد COI اختصاصی: SRCSRMED05_227
- زبان مقاله: انگلیسی
- تعداد مشاهده: 456
نویسندگان
Assistant Professor, Department of Environmental Health Engineering, Behbahan Faculty of Medical Science, Behbahan, Iran
Assistant Professor, Department of Pediatrics, Behbahan Faculty of Medical Science, Behbahan, Iran
Assistant Professor, Department of Environmental Health Engineering, Fasa Faculty of Medical science, Fasa, Iran
Department of Environmental Health Engineering, Evaz School of Health, Larestan University of Medical Sciences, Larestan, Iran
چکیده
Back ground and Aim: Benzene is an important pollutant that is released into the air from diverse sources such as chemical industry, crude oil, petrochemical industries, combustion, etc. It can significantly affect the health of human and environment; therefore, it is necessary to remove it from emissive sources. In this study, Benzene removal from polluted air using a biofilter was assessed.Materials and Methods: A three section biofilter (total height of 140 cm) packed with a mixture of scoria- bagasse –compost was used to remove Benzene from air. Effects of different inlet loading, various EBRTs (30, 60, and 90 s), and the biofilter bed height on the biofilter efficiency were evaluated. Operating time was 80 days. Sampling and measurement were performed according to NIOSH method. Results: Results showed that average removal efficiency (RE) at concentration range of I (1.4-3.2 mg/m3), II (6.5-10.2 mg/m3), and III (16.5-20.5 mg/m3) were 96 ± 8, 91 ± 7 and 87 ± 7 percent, respectively. More than 50% of the total removal of the pollutant was occurred in the first section. Also, the average RE at EBRTs of 30, 60, and 90 seconds was 78 ± 6, 89 ± 8 and 97 ± 6%, respectively. Conclusion: According to the results, it can be concluded that the efficiency of the biofilter is increased by decreasing input loading, and increasing EBRT. In general, the removal efficiency for all the tested input concentrations was satisfactory. Due to the high efficiency, low compactness, and low pressure drop of the bed, it can be concluded the biofilter configuration used in this study is suitable and applicable for the removal of pollutants from airstream.کلیدواژه ها
Air, Treatment, Biofilter, Benzenمقالات مرتبط جدید
اطلاعات بیشتر در مورد COI
COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.
کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.