Evaluation of Preference coronary artery bypass grafting with off-pump techniques than on-pump technique, According to cardiac enzymes and troponin

  • سال انتشار: 1397
  • محل انتشار: سومین کنگره بین المللی پزشکی شخصی ایران
  • کد COI اختصاصی: IPMCMED03_054
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 562
دانلود فایل این مقاله

نویسندگان

Nasim Banayi Boroujeni

Student of Biomedical Research Center Ashkezar Branch, Islamic Azad University Ashkezar, Yazd, Iran

Payam Kheirmand Parizi

Cellular, Colecular and Genetics Center Medical Genetics Center of Genome, Shariati St., Isfahan, Iran

Daryoush Hamidi Alamdari

Assistant Professor Department of Medical BioChemistry, Mashhad University of Medical Science

Mahmood Dehghani Ashkezari

Assistant Professor Department of Medical BioChemistry, Mashhad University of Medical Sciences

چکیده

Introduction: Grafting (CABG) usually is performed using cardiopulmonary bypass. However, this method has several side. recently Off-pump coronary artery bypass surgery is recommended as an alternative to the standard method of using the pump CABG. Methods: In this wide review, deals the review several articles in the field of biochemical markers prevails in the diagnosis of coronary artery bypass grafting off-pump technique over On-pump technique.Results: In different studies have shown that a significant reduction in the release of enzymes and troponin I during surgery with off-pump method, it is an indication that the method is less myocardial injury. The slight changes in cardiac enzymes such as troponin I , AST , CK-MB, CK in serum and information obtained from several articles, including a marked decrease in blood transfusion and shorter duration of the surgery, it can be deduced that the off-pump technique safe and is effective in selected patients with coronary lesions.Conclusions: According to a careful and comprehensive review several articles, it is concluded that off-pump technique in coronary artery bypass surgery safer and better methods of On-pump , and According to sources of serum cardiac enzyme release, and serum troponin I, followed by grafting with off-pump technique , can be said that Damage to the heart this method is lower than other methods. However, more accurate and more comprehensive studies are needed in this issue.

کلیدواژه ها

CABG , cardiac enzymes , troponin , Off-pump and On-pump

مقالات مرتبط جدید

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.