Using the Absorptive-Dissipative Silencer in Air Conditioning Systems of an Office Environment in Order t o Provide Acoustic
- سال انتشار: 1397
- محل انتشار: فصلنامه بهداشت، ایمنی و محیط زیست، دوره: 5، شماره: 4
- کد COI اختصاصی: JR_IJHSE-5-4_008
- زبان مقاله: انگلیسی
- تعداد مشاهده: 464
نویسندگان
Department of Occupational Health Engineering, Occupational and Environmental Health Research Center, School of Public Health, Shahroud University of Medical Sciences, Shahroud, Iran.
Center of Excellence for Occupational Health, Research Center for Health sciences, School of Public Health, HamadanUniversity of Medical Sciences, Hamadan, Iran.
Department of Ergonomics, School of Public Health, Mazandaran University of Medical Sciences, Mazandaran, Iran
Department of Occupational Health Engineering, School of Public Health, Neyshabur University of Medical Sciences,Neyshabur, Iran.
چکیده
Air conditioning systems are the main source of background low frequency noise in administrative buildings,restaurants, classrooms, and hotels. There are different ways to reduce the low frequency noise. Silencers are generictools which are utilized for controlling noise produced by air conditioning systems. Sound assessment and frequencyanalysis were performed in accordance with standard methods to evaluate the exposure of workers in separate workstations. In the next step, an absorptive- dissipative silencer which its inner side was covered by convoluted acousticalfoam was implemented in the ventilation system. The exposure of employees was re-evaluated. Moreover, PreferredNoise Criterion (PNC) and Speech Interference Level (SIL) were two acoustic indices used for assessing theeffectiveness of the silencer. Before implementing the silencer, the sound pressure level in the rooms was between57.8 and 61.1dBA with a peak frequency at 125Hz. The implemented silencer with dimensions of 1.4 ×1×1m, andinlet and outlet area of 0.45×0.45m was able to reduce the sound pressure level of about 13 to 14.2dB. Further, thePNC and the SIL indices were reduced to 14.33 and 15.31dB, respectively. The implemented absorptive- dissipativesilencer reduced the sound pressure level of about 13.6dBA. Moreover, PNC and SIL indices are two important indiceswhich can be used for assessing the level of comfort in office buildings.کلیدواژه ها
Noise Pollution, Silencer, Air Conditioning System, Acoustic Comfortمقالات مرتبط جدید
- New Developments in the Diagnosis and Treatment of Oral and Dental Diseases
- The Impact of Artificial Intelligence in Improving the Design and Production Process of Dental Prostheses
- Capturing Daily Life Factors To Inform Targeted Suicide Prevention Interventions For Young People
- تاثیر عصاره های طبیعی گیاهی در بهبود مسمومیت های حاد کبدی :مقاله مروری
- تاثیر موسیقی بر پیشگیری از سرطان
اطلاعات بیشتر در مورد COI
COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.
کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.