Performance of Extended Aeration Biological System in Removal of Organic Matter from Razi Hospital Wastewater during 2015, Iran
- سال انتشار: 1396
- محل انتشار: مجله آرشیو علوم بهداشتی، دوره: 6، شماره: 3
- کد COI اختصاصی: JR_AHS-6-3_003
- زبان مقاله: انگلیسی
- تعداد مشاهده: 467
نویسندگان
Department of Environmental Health, Khoy School of Medical Sciences, Khoy, Iran
Razi Educational Hospital, Clinical Research Development Center, Ahvaz Jundishapur University of Medical Sciences, Ahvaz,Iran
Abadan School of Medical Sciences, Abadan, Iran- Student Research Committee, Department of Environmental Health Engineering, School of Health and Environmental Technologies Research Center, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
Research Center for Environmental Pollutants, Qom University of Medical Sciences, Qom, Iran
چکیده
Background & Aims of the Study: The most important compounds in hospital wastewater areantibiotics, disinfectants, anesthetics, radioactive elements, static cytotoxic agents, otherchemicals and hazardous materials that caused to be different domestic sewage. The purpose ofthis study was the evaluation of performance of extended aeration biological system in pollutantsremoval from Razi Hospital wastewater treatment plant (WTP), Ahvaz city of Iran.Materials and Methods: The hospital wastewater disposal and treatment in Razi hospital havebeen studied in this cross-sectional research. Total of 12 samples from effluents of wastewatertreatment plants were collected and tested for pH, Biological Oxygen Demand (BOD5),Chemical Oxygen Demand (COD), Total Suspended Solid (TSS) and Total Coliform (TC). EPAstandard method was used for conducted trials. Finally, the relationship between results atdifferent months and stations was done, using SPSS18 and descriptive statistics.Results: Results shown that parameters average in effluent was pH=7.46 ،BOD= 48.58 mg/l,COD=99.25 mg/l, TSS=54 mg/l, NH3=5.65mg/l, Turbidity=29.57 NTU. Also total coliform andfecal coliform of effluent were 46.19 MPN/100 ml and 36.65 MPN/100 ml, respectively.According to results, the percentage of BOD, COD, TSS and TC removal in WTP were 85.21,82.46, 86 and 90.15.Conclusion: Based on these findings, Razi hospital effluent wastewater treatment plant wasmitted at Iran environmental standards for discharge to recipient wasters. Based on the result ofour study, Extended Aeration Biological System is a comparatively suitable process for BOD,COD, TSS and TC removal from hospital wastewater.کلیدواژه ها
Wastewater treatmentHospital wastewaterExtended aerationOrganic matterPollutantsAhvazIranمقالات مرتبط جدید
- مروری سیستماتیک بر عوامل زمینه ای اثرگذار بر شدت درد ادراک شده در سندرم فیبرومیالژیا
- The Impact Of Neurodevelopmental Disorders On Dental Care
- Cardiovascular Effects Of Neurological Diseases
- بررسی عوامل موثر بر اهمال کاری دانشجویان دانشگاه های شهرستان نی ریز
- چالش ها و فرصت های موجود در مسیر تربیت مبتنی بر هویت ایرانی اسلامی در مدارس از دیدگاه دانشجو معلمان دانشگاه فرهنگیان اراک
اطلاعات بیشتر در مورد COI
COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.
کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.