Fabrication of ultrathin graphene oxide-coated membrane with hydrophilic properties for arsenate removal from water
- سال انتشار: 1395
- محل انتشار: مجله پیشرفت در تحقیقات بهداشت محیط، دوره: 4، شماره: 3
- کد COI اختصاصی: JR_JAEHR-4-3_007
- زبان مقاله: انگلیسی
- تعداد مشاهده: 479
نویسندگان
Environmental Health Research Center, Kurdistan University of Medical Sciences, Sanandaj, Iran
Center for Water Quality Research (CWQR), Institute for Environmental Research (IER), Tehran University of Medical Sciences, Tehran, Iran
Department of Environmental Health Engineering, School of Public Health, Tehran University of MedicalSciences, Tehran, Iran
Department of Environmental Health Engineering, Faculty of Health and Nutrition, Lorestan University of Medical Sciences, Khorramabad, Iran
چکیده
Terms and conditions of current drinking water quality standards, including reducing the maximum arsenic concentration from 50 μgl-1 to 10 μgl-1 and predicted stricter standards in future, reveals the necessity for development of new technologies. This study aimed to prepare and evaluate a new nanocomposite membrane using graphene oxide (GO) thin layer to remove arsenic (v) from water. To fabricate the membrane, initially GO was prepared using the modified Hummers method and then to gain a narrow-dispersed GO dispersion, several times centrifugation and sonication were performed. Then resultant dispersed GO was coated on a microporous flat-sheet polyethersulfone support by coating/deposition and vacuum filtration process. Performance of the synthesized membrane was assessed using a dead end filtration system. The results showed that pure water flux decreased as the coated GO thickness increased. Among the three prepared membranes, the greatest flux was attributed to M1 membrane with the value of 398.5 lm-2h-1 and the minimum flux was for M3 with a value of 131.3 lm-2h-1 at 4 bar of pressure. Furthermore, by increasing the coated GO, rejection of arsenate ions increased significantly. With initial concentration of 1000 ± 20 μgl-1, percentage of arsenate rejection for M1, M2 and M3 membranes were 41.8%, 73.5% and 86.7%, respectively. Relatively high removal by this novel membrane can be due to the exceptional properties of GO nanostructure and the presence of hydrophilic functional groups.کلیدواژه ها
Membrane, Nanocomposite, Drinking water, Arsentateمقالات مرتبط جدید
- بررسی تاثیرات مثبت عوامل مدیریت آموزشی در یادگیری دانش آموزان ابتدایی
- مدل یابی روابط ساختاری ویژگی های شخصیتی با ادراک درد در زنان تحت عمل جراحی زایمان با میانجی گری ناگویی هیجانی
- Affective Disorders and General Health Status in Patients with Total Laryngectomy
- مدیریت اصولی و صحیح معلمان در کلاس های درس
- توسعه روان شناختی کودکان و نوجوان از کودکی تا بلوغ
اطلاعات بیشتر در مورد COI
COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.
کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.