The Effect of Recurring on Physical Properties of Concrete Containing Silica-Fume with Improper First Curing

سال انتشار: 1395
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 376

فایل این مقاله در 8 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_QSEJ-5-2_005

تاریخ نمایه سازی: 1 مرداد 1397

چکیده مقاله:

As regards if curing stops for some time and then resumes again, then strength gain will also stop and reactive, in this study with choose suitable curing conditions after improper first curing (recurring) for normal and silica-fume concrete, Effect of this curing conditions on strength and permeability was investigated. The results from tests such as compressive strength, capillary water absorption and water penetration under pressure, indicates that curing after 28 days for concretes with improper first curing, especially for silica-fume concretes could be effective and reduction permeability and increase compressive strength of concretes was observed

کلیدواژه ها:

Recurring ، Silica-fume ، Compressive strength ، Water penetration under pressure ، Capillary Absorption

نویسندگان

Ali Delnavaz

Department of civil and surveying engineering, Qazvin Branch, Islamic Azad University, Qazvin, Iran

Mohammad Reza Pezeshkian

Department of mechanical engineering, Takestan Branch, Islamic Azad University, Takestan, Iran