Ibuprofen Removal from a Pharmaceutical Wastewater using Electro-Fenton Process: An Efficient Technique

سال انتشار: 1396
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 399

فایل این مقاله در 8 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_IJE-30-11_003

تاریخ نمایه سازی: 1 اردیبهشت 1397

چکیده مقاله:

The aim of this research is to evaluate the effective parameters such as pH, current density (mA/cm2), H2O2/Fe2+ molar ratio, volume ratio of H2O2 to pharmaceutical wastewater (PhW) (ml/l) and reaction time (min) on the electro-Fenton process for the ibuprofen (as a pharmaceutical waste in water) removal. Since a synthetic wastewater with the same concentration of ibuprofen in a real pharmaceutical wastewater (400 ppm) was chosen in this research, the sample was tested in terms of the chemical oxygen demand (COD). The parameters were statistically optimized under response surface mythology (RSM). The software was also applied to minimize the number of runs. The optimum conditions for 98.29% COD removal experimentally were at pH of 2.43, current density of 23.08 mA/cm2, H2O2/Fe2+ molar ratio of 2.69, volume ratio of H2O2/PhW of 1.84 ml/l and reaction time of 28.08 min.

کلیدواژه ها:

نویسندگان

R Davarnejad

Department of Chemical Engineering, Faculty of Engineering, Arak University, Arak, Iran

K Zangene

Department of Chemical Engineering, Faculty of Engineering, Arak University, Arak, Iran

A.R Fazlali

Department of Chemical Engineering, Faculty of Engineering, Arak University, Arak, Iran

R Behfar

Department of Chemical Engineering, Faculty of Engineering, Arak University, Arak, Iran