Seismic performance assessment of hybrid braced cold-formed steel walls
- سال انتشار: 1395
- محل انتشار: هفتمین کنفرانس ملی و دومین کنفرانس بین المللی سازه و فولاد
- کد COI اختصاصی: ISSS07_040
- زبان مقاله: انگلیسی
- تعداد مشاهده: 662
نویسندگان
Assistant Professor, Department of Civil Engineering, K. N. Toosi University of Technology, Tehran, Iran
Ph.D., Department of Civil Engineering, K. N. Toosi University of Technology, Tehran, Iran,
Faculty of Engineering, University of Guilan, Rasht, Iran, Ph.D. Student
چکیده
Cold-formed steel (CFS) structures or light weight steel frame (LSF) structures have been frequently used in recent years due to their fast constructions as well as consumed light weight steels. CFS structures are constructed with light thin cold formed steel members. Lateral loading systems of these structures are often steel or wooden shear walls and merely tensional steel cross-straps in the form of shear panels. The performance of lateral loading system with hybrid bracing is evaluated in this study considering the simultaneous use of steel shear wall and strap cross-bracing in different floors of a CFS structure. For this purpose, nonlinear static analysis, linear dynamic analysis and incremental dynamic analysis (IDA) have been conducted on 1-3 storey frames with shear wall, steel strap cross-bracing and hybrid bracing using OpenSees software. Response modification factor (R) is one of the most important seismic parameters of structures against earthquake loads. In fact it shows the capability of structural system in absorbing and dissipating the energy caused by earthquake and creating nonlinear deformations without total collapse of structure. This factor has been calculated here for the mentioned lateral bracing systems. The obtained values are 4.1 and 3.1 for CFS structures with shear wall and cross-bracing, respectively, and 4.9 and 2.8 for hybrid bracing considering the shear wall and bracing in the lower storeys, respectively. Based on the results of this research, it seems that hybrid bracing of shear wall in the lower storeys is one of the best lateral bracing system for cold-formed steel structures.کلیدواژه ها
Cold-Formed Steel Structures, Hybrid Bracing, Incremental Dynamic Analysis, Response Modification Factor, Over Strength Factor, Ductility Factorمقالات مرتبط جدید
- بررسی اثر پارامترهای محیطی (دما، رطوبت) بر داده های پایش سلامت پل های فولادی
- بررسی تاثیر نوع ساینده بر تاول اسمزی پوشش بر پایه اپوکسی بر سطوح فولای آلیاژ کربن در محیط غوطه ور
- مدل اجزای محدود برای ارزیابی تاثیر خروج از مرکزیت بر ظرفیت ورق های پیوستگی در ستون های H شکل
- ارزیابی احتمالاتی قاب خمشی فولادی بر پایه فولاد St۳۷ و St۵۲ تحت زلزله های نزدیک گسل
- خرابی پیشرونده لرزه ای قاب خمشی فولادی ویژه بلند مرتبه مهاربندی شده در برابر زلزله نزدیک گسل
اطلاعات بیشتر در مورد COI
COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.
کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.