Quantifcation of identical and unique segments inethylene-propylene copolymers using two dimensionalliquid chromatography with infra-red detection

  • سال انتشار: 1395
  • محل انتشار: فصلنامه پلی اولفین ها، دوره: 3، شماره: 2
  • کد COI اختصاصی: JR_POJ-3-2_004
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 348
دانلود فایل این مقاله

نویسندگان

Sampat Singh Bhati

Fraunhofer Institute for Structural Durability and System Reliability, Division Plastics, Group MaterialAnalytics, Schlossgartenstrasse ۶, ۶۴۲۸۹, Darmstadt, GermanyDutch Polymer Institute (DPI), P.O. Box ۹۰۲, ۵۶۰۰ AX Eindhoven, the Netherlands

Tibor Macko

Fraunhofer Institute for Structural Durability and System Reliability, Division Plastics, Group MaterialAnalytics, Schlossgartenstrasse ۶, ۶۴۲۸۹, Darmstadt, Germany

Robert Brüll

Fraunhofer Institute for Structural Durability and System Reliability, Division Plastics, Group MaterialAnalytics, Schlossgartenstrasse ۶, ۶۴۲۸۹, Darmstadt, Germany

چکیده

Hyphenating high temperature high performance liquid chromatography (HT-HPLC) with high temperature size exclusion chromatography (HT-SEC) (high temperature two dimensional liquid chromatography (HTHPLC x HT-SEC or HT 2D-LC)) leads to an isocratic elution in the second dimension, which in turn enables touse IR detector (quantitative detection) for monitoring the eluting polymers. Experimental data obtained fromHT 2D-LC with IR detector are usually presented as contour plots, which can be mathematically described inmatrices. Quantitative data about chemical composition, molar mass and concentration of all the segments, whichare present in a polymer, can be obtained, after calibrating the HPLC separation (HPLC elution volume vs chemicalcomposition), SEC separation (SEC separation vs molar mass) and response of the IR detector (IR response vsmass of the polymer). A new procedure based on subtraction and addition of matrices is described, which enablesquantitative comparison of different polymer materials. This procedure enables to determine, which componentsare present in both materials (i.e., identical components or segments) and which are present only in one fromboth the materials (i.e., unique segments). Moreover, molar mass distribution, as well as chemical compositiondistribution of both identical and unique segments is evaluated from experimental data. The procedure was appliedon two different ethylene-propylene copolymer samples. Polyolefns J (2016) 3: 119-133

کلیدواژه ها

ethylene-propylene copolymer; high temperature two-dimensional liquid chromatography; quantitative detection;infra-red detection; size exclusion chromatography

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.