The new mathematical model for prediction of deactivationprocess in Claus sulfur recovery unit

  • سال انتشار: 1395
  • محل انتشار: سومین کنفرانس بین المللی دستاوردهای نوین پژوهشی در شیمی و مهندسی شیمی
  • کد COI اختصاصی: CHECONF03_296
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 332
دانلود فایل این مقاله

نویسندگان

Maryam Asadollahi

School of chemical and petroleum Engineering, Semnan University, Semnan, Iran

Bahman Zarehnezhad

School of chemical and petroleum Engineering, Semnan University, Semnan, Iran

چکیده

The Claus process is still the most important unit operations for sulfur removal and recovery in oil and gas industries. In this work a new model is presented to determine sulfur recovery efficiency and deactivation process. The Coldbed system is replaced catalytic reactor. It enabled attainment of very high conversions of H2S but at the expense of fouling and deactivation of the catalysts. The resultscompared with experimental data and showed well agreement.

کلیدواژه ها

Claus process, Catalytic reactors, Cold bed catalytic reactor, Deactivation, Simulation,