SIMULATION OF TROMBE WALL IN BAGHDAD ATMOSPHERE

  • سال انتشار: 1385
  • محل انتشار: پنجمین همایش بهینه سازی مصرف سوخت در ساختمان
  • کد COI اختصاصی: CECB05_024
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 2973
دانلود فایل این مقاله

نویسندگان

Prof. Jalal M. Jalil

Staff representativeStaff representative Edu. Tech. Dept University of Technology

Dr. Khudheyer S. Mushatet

Dean of engineering college University of Thi-Qar Thi-Qar, Iraq

Sajda S. Faris

LecturierMech. Eng. Dept University of Technology

چکیده

A finite volume method was used to solve the fully Navier-Stokes and energy equations for the problems of turbulent flow and heat transfer characteristics through room with Trombe wall. The Trombe wall system is applied to four materials : concrete, light concrete, masonry, and also paraffin wax type (n-eicosene) to heat a room whose dimensions are (3*2*2)m in climatic conditions of Baghdad in winter months namely, (Dec, Jan, Feb). The thickness of the wall was changed for every material from the above mentioned materials. Three inlet velocities (0.5, 2, 4) m/s was applied on this system. The velocity and temperatures distribution are predicted.

کلیدواژه ها

Trombe wall, CFD, passive solar