Numerical studies on the application of Tuned Liquid Dampers to control seismic response of SDOF systems using SPH method

  • سال انتشار: 1395
  • محل انتشار: کنفرانس بین المللی مهندسی عمران
  • کد COI اختصاصی: CCIVIL01_006
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 630
دانلود فایل این مقاله

نویسندگان

a karamnasab

Department of Civil Engineering, Isfahan University of Technology

m.r chamani

Department of Civil Engineering, Isfahan University of Technology

a.m halabian

Department of Civil Engineering, Isfahan University of Technology

چکیده

Tuned Liquid Dampers (TLD) are passive dampers, working based on shallow liquid sloshing in rigid tanks to suppress the horizontal structural vibrations induced by wind or other dynamics loads. In this paper, TLD application has been investigated using Smoothed Particle Hydrodynamics (SPH) as a numerical tool to model 2D rectangular liquid sloshing absorbers to control ground-induced vibrations. Using SPH, the predicted inertia forces and water wave of a rectangular tank due to harmonic excitation with different frequencies were compared with the results obtained from Boundary Element Method (BEM) and experimental data as well. In addition, the effect of TLD on seismic response of a SDOF structure has been investigated and the results were compared with experimental data.

کلیدواژه ها

tuned liquid damper, TLD, SPH, inertia force, harmonic excitation, random excitation

مقالات مرتبط جدید

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.