High Impedance Restricted Earth Fault Protection: Fundamental Concepts, Design and Performance
محل انتشار: کنفرانس بین المللی مهندسی برق
سال انتشار: 1395
نوع سند: مقاله کنفرانسی
زبان: انگلیسی
مشاهده: 1,039
فایل این مقاله در 6 صفحه با فرمت PDF و WORD قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
ICELE01_082
تاریخ نمایه سازی: 21 شهریور 1395
چکیده مقاله:
Power transformers are a critical and expensive component of the power system. The comprehensive transformer protection provided by combination of protection elements, with biased differential protection. Differential protection has excellent operation in most fault cases, but in the situations that a single phase to ground fault occurs near the neutral point in solidly grounded transformers, the faulted phase current increases slightly and causes differential protection not to detect the fault. For this reason, restricted earth fault (REF) relay can be used as a complementary of differential protection. REF protection uses the sufficient current that flows in this condition through the neutral conductor, for relay operation under phase to ground fault. The REF protection scheme is composed of two parts: a high impedance REF unit and a low impedance REF unit. The high impedance REF relay is defined as a relay circuit whose voltage setting is not less than its calculated maximum terminal voltage which corresponds to the maximum through fault current under transient condition. This REF protection scheme provides a high speed and absolutely stable means of protection when ground fault occurs near the windings neutral point in a solidly grounded transformer. This paper summarizes the operating principle of a high impedance protection unit, its relay sensitivity, related CT requirements, importance of a reliable protection, and the necessary setting consideration to be incorporated besides a transformer differential relay
کلیدواژه ها:
نویسندگان
Mohammad Gholami
Electrical Engineering Department, Sharif University of Technology, Tehran, Iran
Ehsan Hajipour
Electrical Engineering Department, Sharif University of Technology, Tehran, Iran
Mehdi Vakilian
Electrical Engineering Department, Sharif University of Technology, Tehran, Iran
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :