CIVILICA We Respect the Science
(ناشر تخصصی کنفرانسهای کشور / شماره مجوز انتشارات از وزارت فرهنگ و ارشاد اسلامی: ۸۹۷۱)

Security Constrained Unit Commitment in Power SystemsUsing Hourly Demand Response and Renewable Energy

عنوان مقاله: Security Constrained Unit Commitment in Power SystemsUsing Hourly Demand Response and Renewable Energy
شناسه ملی مقاله: ICESCON03_120
منتشر شده در سومین کنفرانس بین المللی علوم و مهندسی در سال 1395
مشخصات نویسندگان مقاله:

Ehsan Kianmehr - Department of Electrical Engineering, Doroud Branch, Islamic Azad University, Doroud, Iran
Reza Saki - Department of Electrical Engineering, Doroud Branch, Islamic Azad University, Doroud, Iran
Amir Yarahmadi - Department of Electrical Engineering, Beheshti University, Tehran, Iran

خلاصه مقاله:
Integration of wind units into power system introduce various sourcesof technical and economical challenges to operation of power systemdue to its inherent uncertainty and variability. In operation of powersystem, stochastic wind generation can affect on the system security. Inthis paper, optimal security-constrained unit commitment (SCUC) inpresence of demand response program (DR) based on stochastic windgeneration is proposed as a novel method of SCUC to address thementioned concern. In order to secure system from stochastic windgeneration, the SCUC results have to be valid for most probable windgeneration scenarios. The problem is formulated as a mixed-integerprogramming (MIP) and solved using Benders decomposition whichimplemented using GAMS software (CPLEX solver). The results ofapplying proposed method on IEEE six-bus test system show that theproposed method can successfully find the optimal SCUC whichsatisfied all constraints while is secure against variations in windgeneration..

کلمات کلیدی:
Security-constraint unit commitment (SCUC); Stochasticwind generation; Demand response (DR); Benders decomposition

صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/491566/