Evaluation of Electrochemical process on Polyphosphate Removal from the Aqueous Solution

  • سال انتشار: 1394
  • محل انتشار: نشریه بین المللی علوم بهداشت، دوره: 2، شماره: 2
  • کد COI اختصاصی: JR_IAHS-2-2_001
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 542
دانلود فایل این مقاله

نویسندگان

M.B miranzadeh

PhD, Social Determinants of Health Research Center and Environmental Health Engineering Department, Health School , Kashan University of Medical Sciences, Kashan, Iran

S Dehghan

MSc, Social Determinants of Health Research Center and Environmental Health Engineering Department, Health School , Kashan University of Medical Sciences, Kashan, Iran

F Ghadami

MSc, Social Determinants of Health Research Center and Environmental Health Engineering Department, Health School , Kashan University of Medical Sciences, Kashan, Iran

D Rabbani

PhD, Social Determinants of Health Research Center and Environmental Health Engineering Department, Health School , Kashan University of Medical Sciences, Kashan, Iran

چکیده

Aims The effect of electrochemical process on polyphosphate alone has not been yetinvestigated. The aim of this study was to study polyphosphate removal from syntheticwastewater by electrochemical process.Materials & Methods This research was carried out experimentally on 50 samples ofsynthetic wastewater. In each run 2000ml of SW took place in a batch. A constant 600mAdirect current was applied on the batch content through steel electrodes. First syntheticwastewater samples with initial concentrations in the range of 2-16mgL-1-P were examinedand one sample was taken every 2min during 12min. Then samples in the range of 2 to32mgL-1-P were tested and one sample was taken every 10min during 1 hour. Residualphosphorous in taken samples was measured according to Standard Methods book.Findings The removal efficiency was 85-99.85%. Residual phosphorous concentrationwas reduced below 1mgL-1-P (Iranian standard) in 1.15mA/cm2 DC. The needed reactiontime was 10min. for 2-16mgL-1-P initial concentration whereas at higher concentrationsit was 30min. Also, the reaction was first order with respect to the residual phosphorousconcentration.Conclusion This process is efficient for removal of the over 99% of poly phosphate fromthe wastewater and able to reduce the residual phosphorous in effluent to less than Iranianstandard limits for reuse (≤1mgL-1).

کلیدواژه ها

Electrochemical Techniques; Polyphosphates; Waste Water

مقالات مرتبط جدید

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.