A Comparative Study on a Tilt-Integral-Derivative Controller with Proportional-Integral-Derivative Controller for a Pacemaker
- سال انتشار: 1394
- محل انتشار: کنفرانس بین المللی مهندسی و علوم کاربردی
- کد COI اختصاصی: ICEASCONF01_097
- زبان مقاله: انگلیسی
- تعداد مشاهده: 795
نویسندگان
Department of Biomedical Engineering, East Azarbayjan Science and Research Branch, Islamic Azad University, Tabriz, Iran
Faculty of Electrical Engineering, University of Tabriz, Tabriz, Iran
چکیده
The study is done to determine the comparison between proportional-integral-derivative controller (PID controller) and tilt-integral-derivative (TID controller) for cardiac pacemaker systems, which can automatically control the heart rate to accurately track a desired preset profile. These controllers offer good adaption of heart to the physiological needs of the patient. The parameters of the both controllers are tuned by particle swarm optimization (PSO) algorithm which uses the integral of time square error as a fitness function to be minimized. Simulation results are performed on the developed cardiovascular system of humans and results demonstrate that the TID controllers produces superior control performance than PID controllers. In this paper all simulations were performed in.کلیدواژه ها
integral of time square error; pacemaker systems; particle swarm optimization algorithm; proportional-integral-derivative controller; tilt-integral-derivative controllerاطلاعات بیشتر در مورد COI
COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.
کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.