A study of soil-welded steel grid reinforcement interface friction by pull-out test

  • سال انتشار: 1394
  • محل انتشار: دومین کنفرانس ملی مکانیک خاک و مهندسی پی
  • کد COI اختصاصی: SMFE02_575
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 736
دانلود فایل این مقاله

نویسندگان

S.H Lajevardi

D Dias

Grenoble Alpes University, Grenoble, France

J Racinais

MENARD, Nozay, France

چکیده

The interface friction coefficient is an important design parameter for reinforced soil structures where thefriction between the soil and reinforcement elements is mobilized. The pull-out test is the most commonlyadopted method to identify this friction coefficient. In this paper, 18 pull-out tests were conducted on twotypes of welded steel grids embedded in a sand to investigate the soil/reinforcement interaction. The testswere conducted under vertical stresses ranging from 20 to 140kPa on the reinforcement. Ju et al. (2004)developed a new test method based on a staged pull-out test for extensible reinforcements. In this studyand for inextensible reinforcement, this new test method has also been used. In a usual pull-out test, onlyone vertical stress has been used. For a staged pull-out test, several vertical stresses are used. The resultsof staged pull-out tests are in good agreement with results of usual pull-out test.

کلیدواژه ها

Pull-out test, Welded steel grid, Friction coefficient, Soil reinforcement

مقالات مرتبط جدید

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.