Survey of Poly Aluminum Chloride as CoagulantForOrganicmatter, Turbidity and MicroorganismsremovalFrom Karoon River in Iran
- سال انتشار: 1394
- محل انتشار: کنفرانس بین المللی علوم، مهندسی و فناوری های محیط زیست
- کد COI اختصاصی: CESET01_419
- زبان مقاله: انگلیسی
- تعداد مشاهده: 830
نویسندگان
Associate Professor, department of environmental health, and Environmental technologies research center ,Ahvaz Jundi Shapur university of medical sciences, Ahvaz,Iran
Department of environmental health, Ahvaz Jundi Shapur university of medical sciences, Ahvaz, Iran
Associate Professor, department of environmental health, and Environmental technologies researchcenter ,Ahvaz Jundi Shapur university of medical sciences, Ahvaz,Iran
چکیده
PAC hydrolyses with great ease as compared to alum, emitting polyhydroxides with long molecularchains & greater electrical charge in the solution, thus contributing to maximize the physical action of theflocculation. Better coagulation is obtainedwith PAC as compared to alum at medium & high turbidity waters.Floc formation with PAC is quite rapid. The sludge produced by PAC is more compact than that produced byalum.The study was carried out at Water Treatment Plant. in order to determine the optimum conditions of PAC performance in turbidity, coliform bacteria and heterotrophic bacteria removal, tests were performed based on variables such as coagulant dose (3,5,8,10,15,20,30,40,50 mg/Lit), pH(5.5, 6, 6.5, 7, 7.5, 8) and turbidity between 33-100 NTU. The residual turbidity and microbial parameters of samples were measured and coagulant performance in turbidity and microbial parameter removal were determined. The results showed that the most optimal conditions for turbidity removal and microbial parameters efficiency by PAC were pH=8, flash mixing =120 rpm and the optimal doses of PAC were obtained as 10 and 30 ppm. The turbidity, total coliform, fecal coliform and Heterotrophic bacteria removal efficiency under optimum condition of PAC application for dose 10ppm were, respectively, 96.59, 90, 82.75, 84.17% while turbidity, total coliform, fecal coliform and heterotrophic bacteria removal efficiency under optimum condition of PAC dose of 30ppm was 99 , 94.65 , 88.94 , 90.47%, respectively.کلیدواژه ها
Karoon river, AhvazWater treatment,PolyAluminumChloride,Turbidity,Coliformمقالات مرتبط جدید
- استفاده از مواد سازگار با محیط زیست در صنعت ساختمان بتن سبز و بازیافتی رویکردی موثر در توسعه پایدار
- بررسی جایگاه مناطق حفاظت شده ایران و نقش مشارکت های مردمی در حفاظت از مناطق
- مروری بر مقایسه اثر سمیت نانوذرات فلزی مختلف، روی آبشش ماهی ها
- مطالعه مدیریت ازن و عوامل آلودگی محیط زیست
- پارامترهای محیط زیستی یا فعالیت های انسانی کدام یک بیشترین تاثیر را بر غلظت متان اتمسفری ایران دارند؟
اطلاعات بیشتر در مورد COI
COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.
کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.