Uncertainty analysis in the neutronic parameters generation for BWR and PWR coupled thermal-hydraulic–neutronic simulations

  • سال انتشار: 1393
  • محل انتشار: اولین کنگره سراسری فناوریهای نوین ایران با هدف دستیابی به توسعه پایدار
  • کد COI اختصاصی: SENACONF01_249
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 709
دانلود فایل این مقاله

نویسندگان

Seyed Mahdi Mostashiri

University of Amirkabir Industrial, Tehran, Iran

Ali Haghighi Shad

University of Amirkabir Industrial, Tehran, Iran

Heidar Abbasi

heidar.abbasi@yahoo.com

Narges Ghasempoor

Hakim Sabzevari University, Applicable physic - elementary particle physic, Iran

چکیده

The Best Estimate analysis consists of a coupled thermal-hydraulic and neutronic description of the nuclear system’s behavior; uncertainties from both aspects should be included and jointly propagated. This paper presents a study of the influence of the uncertainty in the macroscopic neutronic information that describes a three-dimensional core model on the most relevant results of the simulation of a Reactivity Induced Accident (RIA). The analyses of a BWR-RIA and a PWR-RIA have been carried out with a three-dimensional thermalhydraulic and neutronic model for the coupled system TRACE-PARCS and RELAP-PARCS.

کلیدواژه ها

Uncertainty analysis, Neutronic parameters, BWR, PWR