This study focuses on the performance of H-shaped steel beams to CFT column rigid connections. Tothis end, the effects of internal and external stiffeners on hysteretic behavior of connections werestudied. Comparative numerical analyses were carried out on eight different connections. To thisend,finite element models were prepared using ANSYS and nonlinear cyclic analyses were carried out.Results of this study revealed that external stiffeners are key elements to increase the ductility andstrength of steel beam to CFT column connections. The connections with internal stiffeners, withoutany external stiffeners did not exhibit observable hysteretic behavior. On the other hands T-shapedstiffened connections exhibited stable hysteresis loops. Furthermore the capacities of T-stiffenedconnections were about 1.75 times greater than that of models with horizontal or vertical stiffeners

کلیدواژه ها

CFT ColumnsHysteretic BehaviorNonlinear AnalysisDuctility