SINGLE-BLOW TEST FOR EVALUATION OF HEAT TRANSFER PERFORMANCE OF PERFORATED-PLATES

  • سال انتشار: 1385
  • محل انتشار: چهاردهمین کنفرانس سالانه مهندسی مکانیک
  • کد COI اختصاصی: ISME14_469
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 1738
دانلود فایل این مقاله

نویسندگان

چکیده

The heat transfer and flow friction characteristics of perforated-plates are important factors in the design of a Matrix Heat Exchanger (MHE). No satisfactory theory exists to predict the overall heat transfer coefficient for a perforated-plate, and this coefficient must be measured under varying geometrical and operating parameters. We have developed analytical techniques to reduce the experimental data of single-blow transient test of discrete plate-spacer pairs. A single-blow transient test set up has been used to determine heat transfer coefficients of stacks of perforated-plates. The results are presented in terms of Nusselt number, given as function of Reynolds number and geometrical parameters.

کلیدواژه ها

Martrix Heat Exchanger – Perforated plates – Single blow Test - Maximum Slope - Heat Transfer Coefficient