Reliability based planning and operation planning of thermal-wind units

  • سال انتشار: 1404
  • محل انتشار: مجله آنالیز غیر خطی و کاربردها، دوره: 16، شماره: 9
  • کد COI اختصاصی: JR_IJNAA-16-9_003
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 39
دانلود فایل این مقاله

نویسندگان

Farzad Arefi

Department of Electrical Engineering, Hamedan Branch, Islamic Azad University, Hamedan, Iran

Hassan Meyar-Naimi

Department of Electrical Engineering, Hamedan Branch, Islamic Azad University, Hamedan, Iran

Ahmad Ghaderi Shamim

Department of Electrical Engineering, Hamedan Branch, Islamic Azad University, Hamedan, Iran

چکیده

Today, the issue of planning and operation planning of thermal units (TUs) based on generation system reliability has become very important due to the restructuring process in power systems, load increment and distributed generation penetration on the demand side. This paper proposes a two-step approach to solve the aforementioned issue in the presence of wind farm renewable energy resources in the electricity market environment. In the first step, the optimal installation capacity of TUs is determined by the goal of providing annual peak load and being at the desired level of generation system risk using the loss of load probability analysis. Their economic dispatch and spinning reserve are determined in the second step. Expected energy not served is used for generation system reliability evaluation in the operation planning phase. Single contingencies of TUs are defined as system uncertainty. It is assumed that wind farm has constant capacity in the planning phase, and it generates active power (negative injection) as a function of wind speed at the installation region in the operation planning phase. Auto Recursive and Moving Average time series model is applied for wind speed estimation at different time intervals in the operation planning phase. The genetic algorithm has been used to solve this optimization problem. To validate the effectiveness of the proposed model, numerical studies and simulations are performed on the standard test generation system with ۳۲ TUs and ۱ wind farm. Finally, conceptual results have been expressed.

کلیدواژه ها

Thermal-wind Units, Operating Reserve, Generation System Reliability, Well-Being Analysis (WBA), Auto Recursive and Moving Average (ARMA)

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.