Investigation on the Effect of Number and Diameter of Nozzles and Inlet Pressure on Performance of a Dual-Circuit Vortex Tube System

  • سال انتشار: 1405
  • محل انتشار: ماهنامه بین المللی مهندسی، دوره: 39، شماره: 1
  • کد COI اختصاصی: JR_IJE-39-1_010
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 28
دانلود فایل این مقاله

نویسندگان

B. Rahimi Sure

Department of Mechanic, Faculty of Technical and Engineering, Qazvin Branch, Islamic Azad University, Qazvin, Iran

F. Kowsary

School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran, Iran

F. Fakhrabadi

Department of Mechanic, Faculty of Technical and Engineering, Qazvin Branch, Islamic Azad University, Qazvin, Iran

چکیده

This study examines the effect of nozzle count, nozzle diameter, and inlet pressure on the cooling and heating efficiency of double-circuit vortex tubes (DCVTs). Vortex tubes, simple devices without moving parts, are widely used but face challenges in optimizing cooling and heating efficiency. To address this issue, ۱۵ different configurations with nozzle counts ranging from ۲ to ۵ and diameters of ۱.۵, ۲, and ۲.۵ mm were tested under inlet pressures of ۸, ۹, and ۱۰ bar, while maintaining the secondary circuit pressure at ۱.۵ bar. Additionally, three-dimensional numerical simulations using the k-ε turbulence model were performed to validate the experimental results. The findings revealed that increasing the nozzle count and diameter leads to a reduction in cooling and heating efficiency due to greater energy dissipation. The optimal performance was achieved with two nozzles of ۱.۵ mm diameter at an inlet pressure of ۹ bar, resulting in a ۲.۴۱% improvement in cooling efficiency and an ۳.۱۰% increase in heating efficiency and a ۱۸.۳۹% improvement in cooling performance coefficient compared to other configurations. Conversely, increasing the inlet pressure to ۱۰ bar caused a ۱.۳۸% decrease in cooling efficiency and a ۲.۵۸% reduction in heating efficiency and a ۸.۱۷% reduction in cooling performance coefficient. This study shows that optimal design enhances energy efficiency and reduces consumption in precise temperature control applications.

کلیدواژه ها

Double-Circuit vortex tube, cooling efficiency, number and diameter of nozzles, inlet pressure