Numerical Analysis Used to Predict the Spread of COVID-۱۹ in a Classroom: TecNM Campus Sur de Guanajuato Case Study

  • سال انتشار: 1404
  • محل انتشار: دوماهنامه مکانیک سیالات کاربردی، دوره: 18، شماره: 7
  • کد COI اختصاصی: JR_JAFM-18-7_003
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 43
دانلود فایل این مقاله

نویسندگان

J. E. E. González-Durán

Polytechnic University of Querétaro, El Marques, Queretaro,۷۶۲۴۰, México

L. Estrada-Rojo

TecNM / Celaya Institute of Technology, Celaya, Guanajuato, ۳۸۰۱۰, México

J. Ortega-Alejos

TecNM/ Higher Technological Institute of Southern Guanajuato, Uriangato, Guanajuato,۳۸۹۸۲, México

E. G. Blanco-Díaz

TecNM/ Higher Technological Institute of Southern Guanajuato, Uriangato, Guanajuato,۳۸۹۸۲, México

J. M. Olivares-Ramírez

Technological University of San Juan del Río, San Juan del Rio, Queretaro, ۷۶۸۰۰, México

J. M. García-Guendulain

Polytechnic University of Querétaro, El Marques, Queretaro,۷۶۲۴۰, México

چکیده

This paper examines the impact of indoor airflow, both natural and forced, on the dispersion and distribution of respiratory droplets produced by the act of sneezing in the context of viral respiratory infections, including but not limited to SARS-CoV-۲ (Covid-۱۹), Mpox (monkeypox), and other viral diseases. A numerical analysis was performed to examine the potential safety zones and the impact of ceiling fan usage in a classroom at the Tecnológico Nacional de México (TecNM) Campus Sur de Guanajuato, which features two windows and one door. The present study employs a simulation of the sneezes of twenty students and one teacher, with a distance separation of ۱.۵ m, within a classroom environment characterized by natural ventilation. The study is performed utilizing Computational Fluid Dynamics (CFD) in conjunction with the Discrete Phase Modelling (DPM) approach to capture the trajectory of particulates. Furthermore, the Navier-Stokes equations are employed to resolve the airflow field within the classroom numerically. The results demonstrate the considerable impact of airflow generated by ceiling fans on the dispersion of particles. The safety zones are situated close to the classroom walls, and the teacher is safeguarded if the ceiling fans are operational and the teacher is upright.

کلیدواژه ها

Airflow, CFD, COVID-۱۹, Discrete phase modeling, Sneeze, Transient numerical analysis