Effectiveness of blended modified biomaterials and coagulants in removing heavy metal ions from drinking water before determination by ICP-OES

  • سال انتشار: 1404
  • محل انتشار: فصلنامه روش های تجزیه در شیمی محیط زیست، دوره: 8، شماره: 1
  • کد COI اختصاصی: JR_AMECJ-8-1_004
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 53
دانلود فایل این مقاله

نویسندگان

- -

Department of Chemistry, Alex Ekwueme Federal University, Ndufu-Alike, Abakaliki, Ebonyi State

- -

Department of Mathematics and Statistics, Alex Ekwueme Federal University, Ndufu-Alike, Abakaliki, Ebonyi State.

- -

Department of Chemistry, University of Agriculture and Environmental Sciences, Umuagwo, Imo State

- -

Department of Chemistry, Alex Ekwueme Federal University, Ndufu-Alike, Abakaliki, Ebonyi State.

- -

Department of Chemistry, University of Agriculture and Environmental Sciences, Umuagwo, Imo State,

چکیده

The effectiveness and characterization of blended composite materials made of modified biomaterials and iron (III) sulfate coagulant to remove selected dissolved heavy metals from water-chosen samples were examined during the rainy and dry seasons by inductively coupled plasma optical emission spectroscopy (ICP-OES). Water samples were mechanically batch agitated at their prevailing pHs with optimal composite doses. Following the treatment during the rainy season, the results indicated a percent elimination range of ۶۲.۱۶-۹۹.۱۹ percent. Cu > Zn > Pb > Cd; Zn > Cu > Pb > Cd; Pb > Cu > Cd > Zn; and Zn > Cu > Cd > Pb were the percent removal trends in the FBW, ABW, EBRW, and ERWA samples, respectively. During the dry season, a removal range of ۹۳.۷۰ – ۱۰۰ percent was recorded with the following trend: Pb = Zn = Cu; Zn Pb; and Pb = Cu. Concentrations of all residual metals except Cd satisfied the World Health Organization and Nigerian Standard Organization permissible levels. Interactions of the variables at (p< ۰.۰۵, p< ۰.۰۱, and p< ۰.۰۰۱) indicated a statistically significant difference. The reduced linear model of analysis of variance (ANOVA) and response surface methodology employed to predict the responses of main and interaction effects of variables for the dosage optimization of composite materials indicated suitability and statistical significance.

کلیدواژه ها

Dissolved Heavy Metals, Inductively coupled plasma optical emission spectroscopy, Biomaterial, Scrap Iron, River water, Borehole Water

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.