Bioanalytical Method Validation and Comparative Bioequivalence Analysis of Amiodarone in Human Plasma Using LC-MS/MS
- سال انتشار: 1403
- محل انتشار: هشتمین کنفرانس بین المللی مطالعات میان رشته ای در نانو فناوری
- کد COI اختصاصی: NANOB08_021
- زبان مقاله: انگلیسی
- تعداد مشاهده: 4
نویسندگان
Payesh Darou Zist Azma Company, East Azerbaijan, Tabriz, Iran
Payesh Darou Zist Azma Company, East Azerbaijan, Tabriz, Iran
چکیده
This study presents the development, validation, and application of a bioanalytical method for quantifying amiodarone in human plasma samples using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The validated method demonstrated specificity, sensitivity, linearity, precision, and accuracy, adhering to ICH M۱۰ and EMEA guidelines. The calibration curve showed excellent linearity over the range of ۶.۲۵ to ۶۰۰ ppb, with correlation coefficients consistently exceeding ۰.۹۹. Sample preparation utilized internal standard calibration with flecainide for accurate quantification, minimizing matrix effects. Analytical recovery was optimized with a mean deviation below ۵%. The bioequivalence study involved volunteers administered with both test and reference formulations of amiodarone, analyzed at multiple time points up to ۷۲ hours post-dosage. Pharmacokinetic parameters such as C_max, T_max, and AUC were determined, indicating bioequivalence within the acceptable regulatory limits. This robust, reproducible method is a valuable tool for clinical pharmacokinetics and therapeutic drug monitoring of amiodarone, ensuring regulatory compliance and enhanced patient care.کلیدواژه ها
Bioequivalence, LC-MS/MS, Amiodarone, Human Plasma, Method Validation, Pharmacokinetics, Internal Standard Calibration, Analytical Chemistryمقالات مرتبط جدید
- کاربرد نانومواد کربنی برای تصفیه فلزات سنگین در آبهای آلوده و اصلاح محیط زیست
- Recent Advances in Regenerative Medicine: The Role of Stem Cells and Biomaterials in Tissue Repair and Regeneration
- PHYSICAL -CHEMICAL PROPERTIES OF TITANIUM ORGANIC COMPOUNDS USING QSPR TECHNIQUES AND TOPOLOGICAL INDICES
- Formation and Characterization of Titanium Dioxide Nano-Layer with Photocatalytic Properties
- Development of Eugenol -Embedded Chitosan -Mesoporous Silica Nanoparticle Antimicrobial Coatings for Biofilm Control on Medical Devices
اطلاعات بیشتر در مورد COI
COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.
کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.