Influence of Normal Tissue Objective Tools on Treatment Planning System in Nasopharyngeal Carcinoma (NPC): A ۳D Printed Anthropomorphic Phantom Study

عنوان مقاله: Influence of Normal Tissue Objective Tools on Treatment Planning System in Nasopharyngeal Carcinoma (NPC): A ۳D Printed Anthropomorphic Phantom Study
شناسه ملی مقاله: JR_IJMP-21-6_008
منتشر شده در در سال 1403
مشخصات نویسندگان مقاله:

Ivory Noersjafrudin - Department of Physics, Institut Teknologi Sepuluh Nopember, Kampus ITS Sukolilo, Surabaya ۶۰۱۱۱, East Java, Indonesia
Ulfi Hanum - Department of Physics, Institut Teknologi Sepuluh Nopember, Kampus ITS Sukolilo, Surabaya ۶۰۱۱۱, East Java, Indonesia
Asmaul Marufah - Department of Physics, Institut Teknologi Sepuluh Nopember, Kampus ITS Sukolilo, Surabaya ۶۰۱۱۱, East Java, Indonesia
Aloysius Putranto - Department of Radiation Oncology, Mochtar Riady Comprehensive Cancer Center (MRCCC) Siloam Hospital Semanggi, Jakarta, ۱۲۹۳۰, Indonesia
Endarko Endarko - Department of Physics, Institut Teknologi Sepuluh Nopember, Kampus ITS Sukolilo – Surabaya ۶۰۱۱۱, East Java, Indonesia

خلاصه مقاله:
Introduction: The normal tissue objective (NTO), one of the new aspects in the radiation treatment planning system (TPS), aims to lower the absorbed dose received by organs at risk (OARs) close to the target volume or Planning Target Volume (PTV). This study was conducted to ascertain the impact of planning in nasopharyngeal cancer (NPC) cases both with and without manual NTO settings.Material and Methods: The study used a ۳D printed head and neck phantom exposed to radiation using the Intensity Modulated Radiation Therapy (IMRT) technique with ۶۰۰۰ cGy prescribed dose and divided into ۳۰ fractions to find the discrepancies between the manually calculated absorbed dose­ and the automatic calculated absorbed dose of TPS. Moreover, evaluation parameter indicators, including the homogeneity index (HI), conformity index (CI), gradient index (GI), and comprehensive quality index (CQI), were used to make comparisons. NTO parameter used in manual plans are f۰ = ۱۰۷%, f∞ = ۶۵%, dose fall-off  = ۰.۰۵ mm-۱, and xstart = ۰.۷۵ cm.Results: The statistical analysis resulted in a significant difference between the calculated absorbed dose and TPS's absorbed dose of Automatic NTO and Manual NTO, whereas, Without NTO plans, there was no statistical difference. The HI values for Automatic NTO, Manual NTO, and Without NTO are ۰.۱۱۸, ۰.۰۵ , and ۰.۰۵۳, respectively. The CI values for Automatic NTO, Manual NTO, and Without NTO are ۰.۹۱, ۰.۹۹, and ۰,۱۹. The GI value for Automatic NTO, Manual NTO, and Without NTO are ۳.۳۴, ۴.۹۴, and ۷.۲۹, respectively. CQI parameter showed that the Automatic NTO plan performs better than the Manual NTO plan based on the maximum dose received by the OAR.Conclusion: In this study, the manual NTO plan showed better performance by reducing hot spots in the central region of PTV.

کلمات کلیدی:
Evaluation Index Parameters, IMRT, Normal Tissue Objective (NTO), Treatment Planning System