Investigation of the Flow Field Characteristics of Aortic Bileaflet Mechanical Heart Valves with Different Leaflet Shapes Using PIV

  • سال انتشار: 1404
  • محل انتشار: دوماهنامه مکانیک سیالات کاربردی، دوره: 18، شماره: 4
  • کد COI اختصاصی: JR_JAFM-18-4_016
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 71
دانلود فایل این مقاله

نویسندگان

Y. Qiang

Key Laboratory of Advanced Pumps, Valves and Fluid Control System of the Ministry of Education, Lanzhou University of Technology, Lanzhou, Gansu Province, ۷۳۰۰۵۰, China

T. C. Duan

Key Laboratory of Advanced Pumps, Valves and Fluid Control System of the Ministry of Education, Lanzhou University of Technology, Lanzhou, Gansu Province, ۷۳۰۰۵۰, China

M. Z. Zhang

Key Laboratory of Advanced Pumps, Valves and Fluid Control System of the Ministry of Education, Lanzhou University of Technology, Lanzhou, Gansu Province, ۷۳۰۰۵۰, China

L. Qi

Cardiovascular Surgery, The First Hospital of Lanzhou University, Lanzhou, Gansu Province, ۷۳۰۰۰۰, China

L. J. Wei

Key Laboratory of Advanced Pumps, Valves and Fluid Control System of the Ministry of Education, Lanzhou University of Technology, Lanzhou, Gansu Province, ۷۳۰۰۵۰, China

چکیده

Non-physiological flow patterns generated by bileaflet mechanical aortic valves are closely associated with thromboembolism following valve replacement surgery. Investigating how different leaflet shapes affect the flow field characteristics of these valves can help optimize leaflet designs to improve hemodynamic performance and reduce postoperative complications. This study used clinical CT imaging data to create a realistic silicone model of the aortic root, setting up an extracorporeal pulsatile flow system to simulate cyclical blood flow. Particle image velocimetry was used to capture the periodic flow field downstream of bileaflet mechanical aortic valves with straight and curved leaflets, analyzing the impact of leaflet shape on velocity distribution, vortex dynamics, viscous shear stress (VSS), and Reynolds shear stress (RSS). Results indicate that the curved leaflets reduced the impact on the aortic sinus, mitigating endothelial cell damage caused by high velocity. The curved leaflet design also increased the effective flow area, preventing blood stagnation and reducing local concentrations of coagulation factors, thus lowering the risk of thrombus formation. The maximum VSS for the straight and curved leaflets were ۱.۹۳ N/m۲ and ۱.۸۷ N/m۲, respectively, while the RSS reached ۱۵۲ N/m۲ and ۱۱۸ N/m۲, respectively. Curved leaflets minimized turbulent shear stress on blood cells, reducing platelet activation and lowering the incidence of thromboembolism. Optimizing leaflet curvature offers a promising avenue for enhancing the hemodynamic performance of bileaflet mechanical aortic valves. Curved designs may also be more suitable for older patients or those with reduced cardiac ejection capacity, improving surgical outcomes and recovery.

کلیدواژه ها

Bileaflet mechanical heart valve, Particle image velocimetry (PIV), Hemodynamics, Leaflet curvature, Shear stress

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.