Validity and Reliability of the Scale Assessment and Rating of Ataxia Persian Version Questionnaire

  • سال انتشار: 1403
  • محل انتشار: مجله پزشکی قلب و قفسه سینه، دوره: 12، شماره: 4
  • کد COI اختصاصی: JR_JCTM-12-4_001
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 79
دانلود فایل این مقاله

نویسندگان

Zahra Saberi

Ear Nose Throat Department, North Khorasan University of Medical Sciences, Bojnurd, Iran

Fatemeh Shahabi

Endoscopic and Minimally Invasive Surgery Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.

Amin Mansouri

Department of Biostatistics, School of Health, Mashhad University of Medical Sciences, Mashhad, Iran.

Vahid Mardani Kalateh Gheshlagh

Ferdowsi University of Mashhad, Mashhad, Iran.

Habibollah Esmaily

Social Determinants of Health Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.

Masoumeh Hassanpour

Endoscopic and Minimally Invasive Surgery Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.

Maryam Saberi-Karimian

Department of Medical Genetics and Molecular Medicine, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.

چکیده

Introduction: The Ataxia Assessment and Rating Scale (SARA) has been validated in English and a standardized tool having translation and modification according to Iranian language and culture was needed. Therefore, we aimed to determine the validity and reliability of the SARA.Methods: This cross-sectional study was conducted among patients with ataxia who were referred to the otolaryngology office from April ۲۰۲۳ to January ۲۰۲۴. The SARA questionnaire consists of ۸ objects that have been translated into Persian. Cronbach’s alpha coefficient was measured to find the internal consistency. Moreover, the intra-class correlation coefficient (ICC) was calculated to evaluate the test-retest reliability. Furthermore, the content validity ratio (CVR) and the content validity index (CVI) were calculated to assess the content validity.Results: A total of ۱۱ patients with ataxia (aged ۴۸.۵±۱۸.۸ years) enrolled in the current study. After examining the face validity, the experts did not mention any particular problem. In the content validity, each CVI and CVR index item was equal to one. Cronbach's alpha obtained was equal to ۰.۸۹۳ that indicates a high level of internal consistency of this scale in the first iteration. In the second iteration, this index was obtained as ۰.۸۹۲. In all the items, except the heel shin item, the value of the ICC could not be estimated because the scores in the first and second iterations were the same. ICC for the heel shin item was equal to ۰.۹۴۴.Conclusion: The Persian version of the SARA questionnaire achieved the necessary validity and reliability and can be used in patients with ataxia to detect the ataxia symptoms and its severity in the country.

کلیدواژه ها

Validity, Reliability, Scale Assessment and Rating of Ataxia, SARA

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.