Evluation of pressure distribution arround the high-pressure gates

  • سال انتشار: 1403
  • محل انتشار: چهاردهمین کنفرانس بین المللی عمران، معماری و مدیریت شهری
  • کد COI اختصاصی: CUCONF14_028
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 105
دانلود فایل این مقاله

نویسندگان

Hamidreza Sajadi

PHD Candidate at K.N.T.U

Mohamadreza Kavianpour

Proffessor at K.N.T.U

Sepide Mostafavi

PHD Candidate at K.N.T.U

چکیده

Bottom outlets are side structures of dams used for supplying downstream water and managing flooddrainage. Two service and emergency gates usually regulate the output flow rate. Estimating thepressure on these gates is crucial for cavitation risk from negative pressures and evaluating the force onthe gates due to the lifting jack design. This force increases with head height and the flow speed in thegates. To calculate the gates lifting force, an appropriate safety factor should be applied, because itsignificantly impacts the vibration of the gates and related equipment like lifting jacks. This researchinvestigates the pressure distribution around bottom sliding outlets using ۱۰ different dam laboratorymodels and analyzes the factors influencing this pressure distribution.

کلیدواژه ها

High-pressure gates, bottom outlet, pressure distribution, downpull force, laboratorymodel.