Solution for Processing Pelvic Bone Metastases with Halcyon TM ۲.۰ on Lateral and Longitudinal Isocenters Treatment Plans Using the VMAT Technique: A Comparative Study
- سال انتشار: 1403
- محل انتشار: مجله فیزیک پزشکی ایران، دوره: 21، شماره: 4
- کد COI اختصاصی: JR_IJMP-21-4_004
- زبان مقاله: انگلیسی
- تعداد مشاهده: 96
نویسندگان
Department of physics, Faculty of sciences, University Mohammed V in Rabat, Morocco
Mohammed VI University of Health Sciences, Casablanca, Morocco
Iba Dosimetry Schwarzenbruck, Germany
Faculty of Sciences, LPHE-M&S, Mohammed V University, Rabat
Université Mohammed V de Rabat
Hassan First University of Settat, High Institute of Health Sciences, Laboratory of Sciences and Health Technologies, Settat, Morocco
Departement of Physics, Laboratory of High Energy Physics, Modelling and Simulation, Faculty of Science, Mohammed V Agdal University, Rabat, Kingdom of Morocco
۱Department of physics, Faculty of sciences, University Mohammed V in Rabat, Morocco
چکیده
Introduction: Treatment of pelvic bone metastases using a Halcyon machine, mostly presents some difficulties to plan, especially for big volumes because of the machine field size. The purpose of this study is to use two lateral isocenters in the treatment of pelvic bone metastases with the Halcyon machine, in order to overcome its limitations in treating large volumes.Material and Methods: We report a retrospective study of ۸ patients who received radiotherapy for pelvic bone metastases, all treated by two different VMAT techniques. The first technique was performed by two longitudinal isocenters (LONI) and the second by two lateral isocenters (LATI) respecting the authorized distance longitudinally between two isocenters which must be less than ۸ cm. For each isocenter, two opposite arcs are used for all treated patients.Results: The plans conformity index (CI) assessment shows no difference between the two used techniques for all the treated patients. Remarkable coverage of PTVs was obtained in lateral isocenter (LATI) with ۹۶.۲% compared to ۹۴%.۶% for LONI, as well as the maximum dose which was ۱۰۹.۴% for LATI versus ۱۱۲.۳% for LONI. However, the Conformation number (CN) that takes into account both healthy tissue and organ at risk protection was improved by ۷.۳% by using LATI.Conclusion: A very satisfactory result has been obtained in the treatment of pelvic bone metastases with LATI. With this technique, we can exceed the limits of the Halcyon machine and process larger volumes.کلیدواژه ها
VMAT, Pelvic, Radiotherapy, PTV, Halcyon Machineاطلاعات بیشتر در مورد COI
COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.
کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.