Over-Response Correction of SNC ۳۵۰p ROOS and PTW Markus Chambers in the Surface Dose and Build-Up Region Dosimetry of ۶MV Photon Beam

  • سال انتشار: 1403
  • محل انتشار: مجله فیزیک پزشکی ایران، دوره: 21، شماره: 4
  • کد COI اختصاصی: JR_IJMP-21-4_009
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 91
دانلود فایل این مقاله

نویسندگان

Deepali Patil

Department of Medical Physics,State Cancer Institute, Indira Gandhi Institute of Medical Sciences,Patna, Bihar.

Mukesh Zope

Indira Gandhi Institute Of Medical Sciences ,Sheikhpura ,Patna

DINESH SAROJ

BALCO Medical Center, Vedanta Research Foundation, New Raipur, atal Nagar, Chhattisgarh ۴۹۳۶۶۱

Aslam P. A.

Department of Radiation Oncology, Kiran Multi Super Speciality Hospital, Surat-۳۹۵۰۰۴, Gujarat.

Basil George

Department of Radiation Oncology, STARLIT Cancer Center, Ahmadabad-۳۸۲۳۵۰, Gujarat.

چکیده

Introduction: The design characteristics of ionization chambers are critical for the accurate measurement of Percentage Surface Dose (PSD) and Percentage Depth Dose (PDD) in the build-up region. This study assesses the over-response correction in PSD and PDD for different field sizes, using Markus and ROOS fixed separation parallel-plate ionization chambers. Material and Methods: The Sun Nuclear Corporation SNC ۳۵۰P ROOS and PTW Markus parallel plate ionization chambers were used to measure ۶ MV photon beam PDD along the central axis in the build-up region.The experiment was performed on a Solid Water® HE phantom with a density of ۱.۰۳۲ g/cm۳.The Measurements were taken at a Source Surface distance (SSD) of ۱۰۰ cm with Field sizes of ۱۰x۱۰cm۲,۲۰x۲۰ cm۲, and ۳۰x۳۰cm۲ and at variable depths. Results: For field sizes of ۱۰x۱۰ cm۲, ۲۰x۲۰ cm۲, and ۳۰x۳۰ cm۲ at a source-to-axis distance (SAD) of ۱۰۰ cm, the PSD values obtained with the Markus chamber, before and after applying Rawlinson's equation for over-response correction, were as follows: ۳۵.۱۱%, ۴۲.۹۲%, ۵۰.۷۲% (before correction) and ۲۸.۳۷%, ۳۶.۱۹%, ۴۴.۰۵% (after correction). Similarly, the PSD values measured using the ROOS chamber, before and after applying over-response correction, were as follows: ۴۱.۶۱%, ۵۰.۵۰%, ۵۸.۰۴% (before correction), and ۳۳.۹۶%, ۴۲.۸۷%, ۵۰.۳۸% (after correction). Conclusion: The application of over-response correction using Rawlinson's equation improved the accuracy of measurements for both chambers, emphasizing the significance of employing appropriate correction techniques to ensure precise dose measurements in the build-up region using ionization chambers.

کلیدواژه ها

Radiation Dosage Percentage Surface Dose Build, Up Dose Dosimeters Radiotherapy