Investigation of the Effects of Transducer Parameters on Adaptive MV Beamformers In Medical Ultrasound Applications
- سال انتشار: 1392
 - محل انتشار: بیست و یکمین کنفرانس مهندسی برق ایران
 - کد COI اختصاصی: ICEE21_569
 - زبان مقاله: انگلیسی
 - تعداد مشاهده: 1389
 
نویسندگان
Ultrasonic Lab, Department of Electrical and Computer Engineering, Tarbiat Modares University, Tehran, Iran
چکیده
In the recent years, various studies have been performed on adaptive beamforming especially for medical ultrasound imaging. In this paper, at first we applied the adaptive Minimum Variance (MV) beamforming to the simulated data derived from Field II. In contrast to conventional beamforming (DAS), MV adaptive beamforming can significantly improve the imaging resolution while retaining the contrast of the image. Then we combined MV with Coherence Factor (CF), by which the resolution and contrast of the medical ultrasound images are simultaneously increased. We implemented these beamformers in the MATLAB and survey the authenticity of them, then fulfil the beamformers with the Visual Studio codes. Those had the same results but execution times of Visual Studio codes are about 13 times lower than other. The major parameters which affect on the image quality are number of elements, height of elements, and sampling frequency. We investigated the effect of these parameters on the image quality by some simulated examples. The results illustrated that the reduction of the number of elements from M=96 to 24 and sampling frequency from 100MHz to 20MHz will degrade quality of the images. Nevertheless, the results of MV beamformer with M=24 and Fs=20MHz are comparable to DAS with M=96 and Fs=100MHz. We illustrated that if height of elements is equal or greater than 5mm, the off-plane targets have a negligible effect on the image quality but if the height of elements is in the same order of the width the off-plane targets have a significant role on the image quality. It should be taken into consideration in using of planar probsکلیدواژه ها
Ultrasound imaging, Adaptive Minimum Variance (MV) beamforming, Coherence Factor (CF), linear arrayمقالات مرتبط جدید
- بهینه سازی مدیریت انرژی در ریزشبکه ها با استفاده از الگوریتم های هوش مصنوعی
 - مبانی، کاربردها و چالشهای یادگیری مشارکتی و تحلیل تجربی و مقایسه ابزارهای یادگیری فدرالی در پیاده سازی مدلهای یادگیری ماشین
 - راهکارهای مبتنی بر هوش مصنوعی برای بهره وری انرژی در تولید سیمان: یک بررسی جامع
 - معماری اینترنت اشیا مبتنی بر هوش مصنوعی در مدیریت انرژی هوشمند
 - سیستم های EMS/BMS در ساختمان های ZEB و نمونههای اجرا شده آن در سطح جهانی
 
اطلاعات بیشتر در مورد COI
COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.
کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.