Determining Effective Parameters on Hydrodynamic Characteristics of Pulsed Packed Column Using ANOVA Method: Determining Optimum Conditions with Maximum Extraction Efficiency

  • سال انتشار: 1400
  • محل انتشار: مجله تحقیقات انتقال حرارت و توده، دوره: 8، شماره: 2
  • کد COI اختصاصی: JR_JHMTR-8-2_010
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 159
دانلود فایل این مقاله

نویسندگان

Mohammad Ghazvehi

Faculty of Chemical, Petroleum and Gas Engineering, Semnan University, Semnan

Masoud Nasiri

Faculty of Chemical, Petroleum and Gas Engineering, Semnan University, Semnan

Mohammad Hasan Mallah

Material and Nuclear Fuel Cycle Research School, Nuclear Science and Technology Research Institute, Tehran, Iran

Jaber Safdari

Material and Nuclear Fuel Cycle Research School, Nuclear Science and Technology Research Institute, Tehran, Iran

چکیده

Using nanoparticles can lead to an increase in mass transfer rate in liquid–liquid extraction systems. Increasing the concentration of nanoparticles in liquids results in the deposition of nanoparticles and thus limits its use in extraction systems. In this paper, the effect of adding a surfactant to nanoparticle in liquid-liquid extraction systems on extraction efficiency is investigated. The effect of surfactant concentration on the extraction efficiency has been investigated both separately and in the presence of nanoparticles. In this research, the effect of continuous and dispersed phase velocity, and pulsation intensity on the hydrodynamic characteristics of the system has been investigated for the first time with the simultaneous use of silica nanoparticles and SDS surfactant in the vertical pulsed packed column. Using hydrodynamic system and in the presence of nanoparticles and surfactant, this research article provides optimum conditions to obtain maximum efficiency with minimum additives and pulsation intensity. ANOVA analysis (three-level Box–Behnken experimental design) has been used to investigate the effective parameters and sensitivity analysis. The results showed that pulsation intensity is the most effective factor on response. With increasing pulsation intensity from ۱ to ۲.۵, the droplet size decreases and hold-up is increased from ۰.۰۲ to ۰.۰۵ (at Qd=Qc= ۲ lit/s) in the system. Also, the effects of adding SiO۲ nanoparticles and Sodium dodecyl sulfate (SDS) surfactant into a chemical system on the hydrodynamic characteristics were studied. The results showed that by adding nanoparticles the droplet size decreases while hold-up increases. Finally, a semi-empirical correlation has been proposed to predict the droplet size in terms of operational parameters, the system chemical properties and the nanoparticle volume fraction. It was found that when pulsation intensity, nanoparticle concentration and surfactant concentration were ۱.۷۵, ۰.۱, and ۰.۰۵, respectively, extraction efficiency increased to ۰.۹۸.

کلیدواژه ها

nanoparticle, surfactant, Pulsed packed column, Mass transfer coefficient, Hold-up, Liquid-liquid extraction

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.