Analysis of Cylindrical Cavity Receiver for Different Heat Losses
عنوان مقاله: Analysis of Cylindrical Cavity Receiver for Different Heat Losses
شناسه ملی مقاله: JR_JHMTR-10-1_004
منتشر شده در در سال 1402
شناسه ملی مقاله: JR_JHMTR-10-1_004
منتشر شده در در سال 1402
مشخصات نویسندگان مقاله:
Vinod Shewale - Department of Mechanical Engineering, NDMVPS KBT College of Engineering, Nashik, India
Arvind Kapse - Department of Mechanical Engineering, NDMVPS KBT College of Engineering, Nashik, India
Shyam Mogal - Department of Mechanical Engineering, NDMVPS KBT College of Engineering, Nashik, India
خلاصه مقاله:
Vinod Shewale - Department of Mechanical Engineering, NDMVPS KBT College of Engineering, Nashik, India
Arvind Kapse - Department of Mechanical Engineering, NDMVPS KBT College of Engineering, Nashik, India
Shyam Mogal - Department of Mechanical Engineering, NDMVPS KBT College of Engineering, Nashik, India
The heat losses are mainly affects on the performance of cavity receiver of solar concentrator. In this paper, the experimental and numerical study is carried out for different heat losses from cylindrical cavity receiver of ۰.۳۵ m cavity diameter and ۰.۵۵ m opening diameter with wind skirt. The total and convection losses are studied experimentally to no wind conditions for the temperature range of ۶۰ °C to ۸۰ °C at ۰°, ۲۵°, ۵۰°, ۷۵° and ۹۰° inclination angle of cavity receiver .The experimental set up mainly consists of cylindrical cavity receiver which is insulated with glass wool insulation to reduce the heat losses from outside surface.. The numerical analysis was carried out with Fluent Computational Fluid Dynamics (CFD) software, to study connective heat losses for no wind condition. The numerical results are compared with experimental results and found good agreement with maximum deviation of ۱۳%. The effect of inclination angle of cavity receiver on total losses & convection losses shows that as the inclination angle increases from ۰o to ۹۰o, both losses decreased due to decreased in convective zone into the cavity receiver. The effect of operating temperature of cavity shows that as the temperature of cavity receiver increases, the total and convective losses goes on increasing. The present results are also compared to the convective losses obtained from M. Prakash. The convective loss from M. Prakash shows nearest prediction to both experimental and numerical results.
کلمات کلیدی: Heat losses, Temperature effect, Cavity receiver, Wind skirt
صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/2072278/