The effect of Geometrical parameters on heat transfer coefficient in helical double tube exchangers
- سال انتشار: 1393
- محل انتشار: مجله تحقیقات انتقال حرارت و توده، دوره: 1، شماره: 2
- کد COI اختصاصی: JR_JHMTR-1-2_003
- زبان مقاله: انگلیسی
- تعداد مشاهده: 113
نویسندگان
Mechanical Engineering Faculty, University of Tabriz, Tabriz, Iran
Mechanical Engineering Faculty, University of Tabriz, Tabriz, Iran
چکیده
Helical coil heat exchangers are widely used in industrial applications ranging fromcryogenic processes, air-conditioning, and nuclear reactors to waste heat recovery due totheir compact size and high heat transfer coefficient. In this kind of heat exchangers, flowand heat transfer are complicated. This paper reports a numerical investigation of theinfluence of different parameters such as coil radius, coil pitch and diameter of tubeon the characteristics of heat transfer in helical double tube heat exchangers usingthe well-known Fluent CFD software. Modeling of the study was implemented based onprinciples of heat transfer, fluid mechanics, and thermodynamics. By imposing boundaryconditions and selecting of an appropriate grid, whereby the results are independent ofmeshing, the obtained results were compared and validated with existing experimentalresults in the open literature. The results indicate that heat transfer augments by increasingof the inner Dean number, inner tube diameter, curvature ratio, and by the reduction of thepitch of the heat exchanger coil.کلیدواژه ها
Helical double tube, Heat exchanger, Curvature ratio, Dean number, Overall heat transfer coefficientاطلاعات بیشتر در مورد COI
COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.
کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.