Numerical Modeling and Experimental Validation of the R-134a Flow through an Adiabatic Helical Capillary Tube
- سال انتشار: 1391
- محل انتشار: همایش ملی مهندسی مکانیک
- کد COI اختصاصی: EASTTEHRANMECH02_130
- زبان مقاله: انگلیسی
- تعداد مشاهده: 1475
نویسندگان
Department of Mechanical and Aerospace Eng., Science and Research Branch, Islamic Azad University, Tehran, Iran
School of Mechanical Engineering, University of Tehran, Tehran, Iran;
۳Department of Mechanical Eng., South Tehran Branch, Islamic Azad University, Tehran, Iran
۴Faculty of Mechanical, Islamic Azad University of Takestan, Gazvin, Iran
چکیده
This paper presents a numerical simulation and an experimental validation of the R-134 flow through the adiabatic helical capillary tubes. The two-phase flow was developed by drift flux model for both straight and helical capillary tubes. The conservation equations of the mass, energy and momentum are numerically solved using the fourth order Runge-Kutta method. This model is validated by previously published experimental and numerical results and also by present experimental results. The effect of various inlet conditions such as pressure, temperature, degrees of sub cooling, and capillary tubes geometric parameters such as tube diameter and length and also coil diameter were studied. Moreover, the pressure variation along helical capillary were experimentally obtained using a closed loop experiment apparatus and vapor quality and void fraction by numerical simulation in same conditions. The comparison between the present measured data and the present developed drift flux model results give an absolute error of 7%. The results of our study show that in the same length and condition, mass flow rate through helical capillary tube with coil diameter of 40 mm is 11% less than that of straight capillary tube where helical type reduces the tube length by 24%. This developed model can be used as an effective tool for designing and optimizing air conditioning with helical capillary tube for various refrigerants.کلیدواژه ها
adiabatic, capillary tube, experimental, helical, numericalمقالات مرتبط جدید
- توسعه مبدل حرارتی داخلی ( IHX ) از طریق تغییر فرآیند ساخت و تولید لوله های گاز کولر در صنعت خودروسازی
- بهبودعملکرد سیکل تبرید تراکمی با تغییر فرآیند ساخت مبدل SLHX از آرایش مماسی به هم مرکز
- بررسی تاثیر لایه میانی روی در اتصال غیر مشابه آلیاژ پایه منیزیم AZ۳۱ و آلومینیوم ۶۰۶۱ به روش جوشکاری اصطکاکی اغتشاشی نقطهای
- بررسی تجربی سوراخکاری کامپوزیتهای پلیمری: مقایسه جوت و شیشه
- سیستم هوشمند پایش وضعیت بلبرینگ با استفاده از طیفنگاره صوتی جهت طبقهبندی و تشخیص خطای بلبرینگ ها
اطلاعات بیشتر در مورد COI
COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.
کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.