Synthesis of gold nanodendrites on hollow carbon spheres as an electrochemical sensorfor the determination of morphine in biological samples
- سال انتشار: 1403
- محل انتشار: بیست و دومین کنگره بین المللی شیمی انجمن شیمی ایران
- کد COI اختصاصی: NICEC22_422
- زبان مقاله: انگلیسی
- تعداد مشاهده: 61
نویسندگان
Research Laboratory of Advanced Water and Wastewater Treatment Processes, Department of Applied Chemistry,Faculty of Chemistry, University of Tabriz, ۵۱۶۶۶-۱۶۴۷۱ Tabriz, Iran.
Research Laboratory of Advanced Water and Wastewater Treatment Processes, Department of Applied Chemistry,Faculty of Chemistry, University of Tabriz, ۵۱۶۶۶-۱۶۴۷۱ Tabriz, Iran.
Department of Chemistry, University of Mohaghegh Ardabili, ۵۶۱۹۹-۱۳۱۳۱ Ardabil, Iran.
Department of Chemistry, University of Mohaghegh Ardabili, ۵۶۱۹۹-۱۳۱۳۱ Ardabil, Iran.
چکیده
In this study, first broken hollow carbon spheres (BHCS) was synthesized using the well-known Stobertemplating method. Then, Au nanodendrites (Au NDs) were loaded on the BHCS modified glassy carbonelectrode by one-step electrodeposition to obtain Au NDs/BHCS/GC electrode as a selective and sensitiveelectrochemical sensor for detecting morphine at low concentration. The proposed electrochemical sensorexhibited a highly selective assay for monitoring of MOR with a wide dynamic linear range ۰.۰۱–۳۰۰ μM,accompanied by a low detection limit of ۸.۳ nM. In addition, the proposed electrochemical sensor hadsatisfactory interference rejection and good stabilityکلیدواژه ها
Nanosensor; Morphine; Au nanodendrites; Broken hollow carbon spheresمقالات مرتبط جدید
- Bioequivalence and Analytical Validation of Linagliptin: A Comprehensive Study Using LC -MS/MS in Human Plasma
- Bioanalytical Method Validation and Bioequivalence Study of Ibrutinib in Human Plasma Using LC -MS/MS: An Advanced Approach
- Bioequivalence Study of Finasteride: Analytical Method Validation and Pharmacokinetic Evaluation in Human Plasma
- Advanced Analytical Method Validation for Bioequivalence Studies of Fexofenadine in Human Plasma Using LC -MS/MS
- Bioequivalence Study of Eplerenone: Analytical Validation in Human Plasma Using LC -MS/MS
اطلاعات بیشتر در مورد COI
COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.
کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.