Solid phase extraction of acetaminophen by magnetic expanded graphite sorbentfunctionalized with glycine and its quantitative determination by gold-silver nanoparticlefunctionalized with polyethyleneimine as a colorimetric sensor
عنوان مقاله: Solid phase extraction of acetaminophen by magnetic expanded graphite sorbentfunctionalized with glycine and its quantitative determination by gold-silver nanoparticlefunctionalized with polyethyleneimine as a colorimetric sensor
شناسه ملی مقاله: NICEC22_358
منتشر شده در بیست و دومین کنگره بین المللی شیمی انجمن شیمی ایران در سال 1403
شناسه ملی مقاله: NICEC22_358
منتشر شده در بیست و دومین کنگره بین المللی شیمی انجمن شیمی ایران در سال 1403
مشخصات نویسندگان مقاله:
Fateme Mohseni Nasrabad - Department of Chemistry, Faculty of Science, Yazd University, Yazd, Iran.
Ali Mohammad Haji Shabani - Department of Chemistry, Faculty of Science, Yazd University, Yazd, Iran.
Shayeste Dadfarnia - Department of Chemistry, Faculty of Science, Yazd University, Yazd, Iran.
Roya Afsharipour - Department of Chemistry, Faculty of Science, Yazd University, Yazd, Iran.Department of Chemistry, Faculty of Science, University of Jiroft, Jiroft ۷۸۶۷۱۶۱۱۶۷, Iran.
Mohammad Javad Jahanshahi - Department of Chemistry, Faculty of Science, University of Jiroft, Jiroft ۷۸۶۷۱۶۱۱۶۷, Iran.
خلاصه مقاله:
Fateme Mohseni Nasrabad - Department of Chemistry, Faculty of Science, Yazd University, Yazd, Iran.
Ali Mohammad Haji Shabani - Department of Chemistry, Faculty of Science, Yazd University, Yazd, Iran.
Shayeste Dadfarnia - Department of Chemistry, Faculty of Science, Yazd University, Yazd, Iran.
Roya Afsharipour - Department of Chemistry, Faculty of Science, Yazd University, Yazd, Iran.Department of Chemistry, Faculty of Science, University of Jiroft, Jiroft ۷۸۶۷۱۶۱۱۶۷, Iran.
Mohammad Javad Jahanshahi - Department of Chemistry, Faculty of Science, University of Jiroft, Jiroft ۷۸۶۷۱۶۱۱۶۷, Iran.
A solid phase extraction method using magnetic expanded graphite sorbent was proposed for theseparation and preconcentration of acetaminophen. The effect of important parameters on the extraction ofanalyte was studied and optimized. The extracted acetaminophen was measured by gold-silver nanoparticlefunctionalized with polyethyleneimine as a colorimetric sensor. The linear range was achieved in the range of۰.۱-۲۰.۰ μg L-۱ for acetaminophen (R۲ = ۰.۹۹۷۲) with a limit of detection of ۰.۰۲۹ g L-۱. The intra-and inter-dayrelative standard deviations for six measurements at the concentration level of ۵.۰ μg L-۱ acetaminophen werefound to be ۲.۶ and ۴.۲ % respectively
کلمات کلیدی: Acetaminophen; Expanded graphite; Gold-silver nanoparticles, Magnetic sorbent
صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/2033976/