Investigating the Effect of Bone Mass Density and Bone Implant Interface on Mandible Stress and StrainUsing Nonlinear Finite Elements Method

  • سال انتشار: 1389
  • محل انتشار: هفدهمین کنفرانس مهندسی پزشکی ایران
  • کد COI اختصاصی: ICBME17_173
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 875
دانلود فایل این مقاله

نویسندگان

Ehsan Atefi

Biomechanics Department School of Mechanical Engineering Iran University of Science and TechnologyTehran, Iran

Mohammadreza Mallakzadeh

Biomechanics Department School of Mechanical Engineering Iran University of Science and TechnologyTehran, Iran

چکیده

The goal of this study is showing the effects of bone mass density and bone-implant interface characteristics onmaximum stress in mandible bone. A 3D nonlinear finite element analysis has been done on a planted titanium cylindrical implant with frictional contact of bone-implant interface. Considering the coulomb frictional contact, maximum Von Misses stress increases in cancellous bone, prominently. It has been shown that cortical bone stress is more sensitive to friction coefficient than cancellous bone. Bone mass density changes with variation of bone strain in specific spans of the strain. Raise of bone mass density in cortical bone increases the stress of cortical bone and decreases the stress of cancellous bone. Sensitivity analysis shows that cortical bonestress is 2.7 times more sensitive compared with cancellous bone.

کلیدواژه ها

Nonlinear Finite Elements Method, Coulomb Frictional Contact, Sensitivity Analysis, Logarithmic Strain, BoneFailure

مقالات مرتبط جدید

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.