The onset of Casson fluid convection in a permeable medium layer produced by purely inner heating with magnetic field
- سال انتشار: 1403
- محل انتشار: مجله مکانیک کاربردی محاسباتی، دوره: 55، شماره: 3
- کد COI اختصاصی: JR_JCAM-55-3_002
- زبان مقاله: انگلیسی
- تعداد مشاهده: 224
نویسندگان
Department of Mathematical & Physical Sciences, University of Nizwa, Nizwa, P.O.B.-۶۱۶, Oman
Department of Mathematics, Babasaheb Bhimrao Ambedkar University, Lucknow ۲۲۶۰۲۵, India
Department of Mathematical & Physical Sciences, University of Nizwa, Nizwa, P.O.B.-۶۱۶, Oman
Department of Applied Sciences, National Institute of Technology Goa, Goa ۴۰۳۴۰۱, India
Department of Mathematics, Institute of Science, Banaras Hindu University, Varanasi–۲۲۱۰۰۵, Uttar Pradesh, India
Department of Mathematics, North Eastern Regional Institute of Science and Technology, Itanagar, Arunachal Pradesh, ۷۹۱۱۰۹, India
چکیده
In this inspection, the control of the magnetic power on the onset of Casson fluid convection formed by purely inner warming in a porous medium layer is examined. The modified Darcy model is employed to designate the rheological arrival of Casson liquid flow in a porous matrix. Two types of thermal boundaries are exploited, namely, type (I) both isothermal and type (II) lower insulated and top isothermal boundaries. Using the linear stability inspection and Galerkin technique, the approximate analytical solution and numerical solution correct to one decimal place are offered. It is detected that for type (I) boundary conditions, the convective wave concentrates in the upper layer if it occurs, whereas for type (II) boundary conditions, it emphases in the whole layer. The magnetic Chandrasekhar number postpones the convection movement while the Casson constraint accelerates it. The facet of the convective cells drops with enhancing the magnetic strength and the Casson constraint. In the absenteeism of magnetic field, the Casson constraint has no regulation on the dimension of convective cells. It is also found that the presented analytical result with two term Galerkin process has overall ۵% error, while with one term Galerkin process the error was overall ۱۹%.کلیدواژه ها
Casson Fluid, Convective motion, magnetic field, Porous medium, Internal Rayleigh numberاطلاعات بیشتر در مورد COI
COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.
کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.