On the Optimization of the Protocol for Automated Radiosyntheses of [۶۸Ga]Ga-Pentixafor, [۶۸Ga]Ga-FAPI-۴ and [۶۸Ga]Ga-DOTATATE in a Modular-Lab Standard

  • سال انتشار: 1403
  • محل انتشار: مجله پزشکی هسته ای و زیست شناسی آسیا اقیانوسیه، دوره: 12، شماره: 2
  • کد COI اختصاصی: JR_JNMB-12-2_006
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 128
دانلود فایل این مقاله

نویسندگان

Sreeja Menon

Health Physics Division, Bhabha Atomic Research Centre, Mumbai, India

Arpit Mitra

Radiopharmaceutical Laboratory, Board of Radiation and Isotope Technology, Navi Mumbai, India

Sudeep Sahu

Radiation Medicine Centre, Bhabha Atomic Research Centre, Mumbai, India

Sangita Lad

Radiation Medicine Centre, Bhabha Atomic Research Centre, Mumbai, India

Avik Chakraborty

Homi Bhabha National Institute, Mumbai, India

Mukti Ray

Homi Bhabha National Institute, Mumbai, India

Sharmila Banerjee

Homi Bhabha National Institute, Mumbai, India

چکیده

Objective: The present work describes the automated radiochemical syntheses of different PET tracers like [۶۸Ga]Ga-Pentixafor, [۶۸Ga]Ga-FAPI-۴ and [۶۸Ga]Ga-DOTATATE using optimized single protocol in the non-cassette based Eckert & Ziegler (EZ) Modular Lab (fixed tubing system) without any modification in the inbuilt human machine interface (HMI) software. Recently, PET agents viz. [۶۸Ga]Ga-Pentixafor and [۶۸Ga]Ga-FAPI-۴ are gaining prominence for the diagnosis of overexpressed Chemokine Receptor-۴ (CXCR۴) and Fibroblast Activation Protein (FAP) receptor, respectively, in the microenvironment of numerous cancer types. The promising results observed with the clinical usage of [۶۸Ga]Ga-DOTATATE produced using the automated protocol, provided impetus for the clinical translation of [۶۸Ga]Ga-Pentixafor and [۶۸Ga]Ga-FAPI-۴ using the in-house developed automated radiolabeling protocol.Methods: Herein we report a single radiolabeling protocol for the automated preparation of [۶۸Ga]Ga-Pentixafor and [۶۸Ga]Ga-FAPI-۴ in the non-cassette based EZ Modular-Lab Standard radiochemistry module, without any changes in schematic, graphical user interface (GUI) software and time list, from that used for routine production of [۶۸Ga]Ga-DOTATATE in our centre, since ۲۰۱۵. Physico-chemical quality control and in-vitro stability analyses were carried out using radio-TLC and radio-HPLC.Results: The automated protocol yielded reliable and consistent non-decay corrected (ndc) radiochemical yield (RCY) of (۸۴.۴±۰.۹)% and (۸۵.۵±۱.۴)% respectively, for [۶۸Ga]Ga-Pentixafor and [۶۸Ga]Ga-FAPI-۴, with RCP> ۹۸%, which are comparable to the RCY of (۸۴.۴±۱.۲)% and RCP (۹۹.۱±۰.۳)% for [۶۸Ga]Ga-DOTATATE. The biological quality control studies confirmed the formulations to be of ready-to-use pharmaceutical grade.Conclusion: The consistent and reliable RCY and RCP of multiple ۶۸Ga-labeled PET tracers by single optimized automated radiochemistry protocol exhibits the versatility of the EZ Modular Lab.

کلیدواژه ها

[۶۸Ga]Ga-Pentixafor, [۶۸Ga]Ga-FAPI-۴, [۶۸Ga]Ga-DOTATATE, Modular-Lab Standard, PET/CT

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.