Ultrasonographic Measurement of the Anterior and Posterior Lens Capsules of the Eyes and its Comparison with a Field Study in Normal Rabbit

  • سال انتشار: 1387
  • محل انتشار: دوفصلنامه جراحی دامپزشکی، دوره: 3، شماره: 3
  • کد COI اختصاصی: JR_IJVS-3-3_001
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 114
دانلود فایل این مقاله

نویسندگان

Varia Tohidi

Department of Clinical Sciences, Faculty of Specialized Veterinary Sciences, Science and Research branch, Islamic Azad University, Tehran, Iran.

Abbas Veshkini

Department of Clinical Sciences, Faculty of Specialized Veterinary Sciences, Science and Research branch, Islamic Azad University, Tehran, Iran.

Mohammad Razi Esfahani

Department of Ophthalmology, School of Medicine, University of Tehran, Tehran, Iran.

Niloufar Piri

Department of Ophthalmology, School of Medicine, University of Tehran, Tehran, Iran.

Alireza Vajhi

Department of Clinical Sciences, Faculty of Veterinary Medicine, University of Tehran, Tehran, Iran.

Mohammad Nasrollahzadeh Masouleh

Department of Clinical Sciences, Faculty of Specialized Veterinary Sciences, Science and Research branch, Islamic Azad University, Tehran, Iran.

Majid Masoudifard

Department of Clinical Sciences, Faculty of Veterinary Medicine, University of Tehran, Tehran, Iran.

Farrokh Reza Kabir

Department of Clinical Sciences, Faculty of Veterinary Medicine, University of Tehran, Tehran, Iran.

چکیده

Objective- To find normal value of thickness of the lens capsules in domesticated rabbits by ultrasonography. Design- experimental in vivo study and clinical trial. Animals- Twelve matured and immature domesticated rabbit. Procedures- The eyes of ۱۲ non anaesthetized domesticated rabbits were sonograophed using a linear ۶-۱۲ MHz high frequency transducer. The thickness of anterior and posterior capsule of the lens was measured in millimeter (mm). All measurements’ were done only by one experienced radiologist and confirmed by another radiologist. Mean and standard errors were calculated statistically by spss statistical software. Results were compared with ultrasonography of the eye of ۷۵ rabbits referred to different small animal clinic and sonographed by a radiologist. Results- The measurement of the thickness of anterior and posterior capsule of both eyes was ۰.۳۹۷۹ ± ۰.۰۳۲۵۵. The mean value and standard deviation of ۷۵ clinically studied rabbits was ۰.۳۹۳۳ ± ۰.۰۲۵۵۲. Conclusion and Clinical Relevance- The thickness of lens capsule can be measured by ultrasonography and this value can be used for diagnosis of production of capsular cataract either experimentally or acquired in rabbit. There was no significant difference between thickness of anterior and posterior capsules of both eyes and has no relation to sex, weight and age of animal.

کلیدواژه ها

Rabbit, Eye, Lens, Ultrasonography

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.