Quantitative and Qualitative Scintigraphic Measurement of Renal Function in Persian Cat Using ۹۹mTechnetium Ethylenedicysteine and ۹۹mTechnetium Diethylenetriaminepentaacetic
- سال انتشار: 1391
- محل انتشار: دوفصلنامه جراحی دامپزشکی، دوره: 7، شماره: 1
- کد COI اختصاصی: JR_IJVS-7-1_005
- زبان مقاله: انگلیسی
- تعداد مشاهده: 75
نویسندگان
Department of Clinical Sciences, Faculty of Veterinary Medicine, Shahid Bahonar University of Kerman, Kerman, Iran.
چکیده
Objective- To consider the use of renal scintigraphic evaluation of kidney function in Persian cat and make a comparison between ۹۹mTechnetium ethylenedicysteine and ۹۹mTechnetium diethylenetriaminepentaacetic in renal scintigraphy.Design- Descriptive studyAnimals- ۶ male healthy adult Persian cats - no clinical sign of renal disorders and prior to presentation.Procedure- The scintigraphy of right and left kidney using Gamma camera (Piker Model) and ۹۹mTc-EC and ۹۹mTc-DTPA as radiopharmaceuticals. Peak activity percentage (% PA), peak time (Tmax), half emptying-time (T۱/۲), total and individual GFR and flow and function time activity curves (TACs) are the determined parameters in this evaluation.Results- % PA, Tmax and T۱/۲ in left and right kidney for ۹۹mTc-EC and ۹۹mTc-DTPA respectively, were ۴۹/۸۶ %, ۵۰/۱ %, ۱۱/۳ min, ۱۱/۵ min, ۴/۴ min, ۴/۶ min and ۵۱/۲۷ %, ۴۹/۰۵ %, ۷/۷ min, ۸/۳ min, ۳ min, ۳/۴۳ min.Moreover the quantities of total and individual GFR for left and right kidney measured by ۹۹mTc-DTPA measured by modified Gates technique respectively, were ۱۲۵/۶۹ ml/min, ۶۴/۴۲ml/min (۵۱/۲۶ %), ۶۱/۲۴ml/min (۴۸/۷۳ %) and were in normal range defined by Gates technique.Conclusion and Clinical Relevance- normal indices obtained for listed parameters and total and individual GFR quantities can play a major role in order to diagnose kidney disorder or function deterioration and can be a background and specialized knowledge conducive to future studies.Also comparison of two radiopharmaceuticals ۹۹mTc-EC and ۹۹mTc-DTPA showed that ۹۹mTc-DTPA scintigraphy has the superiority to assess the quantities of total and individual GFR so we can use ۹۹mTc-DTPA to evaluate Glomerular filtration rate in both kidneys.کلیدواژه ها
scintigraphy, Kidney, Catاطلاعات بیشتر در مورد COI
COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.
کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.