Outcomes of Megaprosthesis Reconstruction for the Salvage of Failed Osteoarticular Allograft Around the Knee implanted before Skeletal Maturity in Primary Bone Sarcoma: A Case-Series
- سال انتشار: 1403
- محل انتشار: مجله استخوان و جراحی عمومی، دوره: 12، شماره: 3
- کد COI اختصاصی: JR_TABO-12-3_009
- زبان مقاله: انگلیسی
- تعداد مشاهده: 106
نویسندگان
Bone and Joint Reconstruction Research Center, Department of Orthopedics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
Bone and Joint Reconstruction Research Center, Department of Orthopedics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
Bone and Joint Reconstruction Research Center, Department of Orthopedics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
Bone and Joint Reconstruction Research Center, Department of Orthopedics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
چکیده
Objectives: Functional expectations following the salvage of a failed osteoarticular allograft are poorly described. In this study, we aim to evaluate functional outcomes, implant survival, and complications of the megaprosthesis in salvaging a failed osteoarticular allograft around the knee.Methods: We retrospectively reviewed the medical profiles of ۲۱ skeletally mature patients who underwent megaprosthesis reconstruction to salvage a failed osteoarticular allograft around the knee implanted before skeletal maturity. The location of reconstruction was the proximal tibia in ۱۳ patients and the distal femur in eight patients. Knee function was evaluated by the Musculoskeletal Tumor Society (MSTS) score and the Toronto Extremity Salvage Score (TESS).Results: The mean age of patients was ۱۶±۱.۷ years. The mean interval between the primary (allograft) and secondary (megaprosthesis) reconstructions was ۵۹.۴±۲۳.۶ months. At an average follow-up of ۵۱.۲ months, the mean knee range of motion was ۱۰۱.۲±۱۵.۶°. The mean MSTS score and TESS were ۸۳.۶±۷ and ۸۶.۶±۷.۹, respectively. The mean limb length discrepancy was ۲.۵±۱ cm before and ۰.۳۶±۰.۷۴ cm after the operation (P< ۰.۰۰۱). Six postoperative complications (۲۸.۶%) occurred in this series, including one wound dehiscence, one periprosthetic fracture, two acute infections, one aseptic loosening, and one delayed periprosthetic infection. Only the last two complications required revision. Accordingly, the two- and five-year implant survivals were ۹۵.۷% and ۹۰%, respectively.Conclusion: Megaprosthesis is a viable option for salvaging failed osteoarticular allografts around the knee. It also provides the opportunity to correct the limb length discrepancy. Level of evidence: IVکلیدواژه ها
Bone tumor, knee, oncologic prosthesis, Osteoarticular Allograft, salvageاطلاعات بیشتر در مورد COI
COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.
کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.