The Efficacy of Riboflavin for Collagen Cross-Linking and Optimizing the Bond Strength of an Etch and Rinse Adhesive System to Dentin

  • سال انتشار: 1396
  • محل انتشار: مجله تحقیقات دندانپزشکی، دوره: 9، شماره: 3
  • کد COI اختصاصی: JR_AJDR-9-3_002
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 60
دانلود فایل این مقاله

نویسندگان

Shahin Kasraei

Mona Malek

Zahra Khamverdi

Maryam Mojtahedi

چکیده

Background and Objectives: Previous studies have shown that increasing collagen resistance to degradation stabilizes the resindentin interface and collagen cross-linkers can prevent the degradation of collagen fibrils as such. This study sought to assess the efficacy of light-activated riboflavin for collagen cross-linking and optimizing the micro tensile bond strength (µTBS) of an etch and rinse adhesive system to dentin. Methods: Occlusal surfaces of ۱۲ sound premolars were ground in order to expose dentin. The teeth were randomly divided into two groups. Adper single bond was applied on etched dentin and light cured in the control group and Composite was then applied. In the test group, all the steps were done in a similar manner to the control group with the difference that after acid etching, ۰.۱% riboflavin solution was applied on dentin surface and was activated by blue light irradiation for ۲ minutes. After thermocycling, the teeth were sectioned in ۲ directions in such a way that ۱۴ resin-dentin sticks with ۱ mm۲ cross-section were prepared in each group (n = ۱۴). The µTBS of samples was then measured and analyzed with independent t-test. The statistical analyses’ significance level was set at α = ۰.۰۵. Mode of failure was determined under a stereomicroscope at × ۴۰ magnification. Moreover, the crosslinking effect of light-activated riboflavin solution on type I collagen was assessed using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) and resin-dentin interface was photographed under a scanning electron microscope (SEM). Results: In gel electrophoresis, bands were formed in wells in the test group (and not in the negative control group). T-test found no significant difference in the mean µTBS of the test and the control groups (P = ۰.۹). Conclusions: Based on the results, light-activated riboflavin was capable of collagen cross-linking, but its application as a collagen cross-linker on etched dentin had no significant effect on µTBS of Single Bond dentin bonding agent to dentin.

کلیدواژه ها

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.