CIVILICA We Respect the Science
(ناشر تخصصی کنفرانسهای کشور / شماره مجوز انتشارات از وزارت فرهنگ و ارشاد اسلامی: ۸۹۷۱)

A Hardware-Software System for Accurate Segmentation of Phonocardiogram Signal

عنوان مقاله: A Hardware-Software System for Accurate Segmentation of Phonocardiogram Signal
شناسه ملی مقاله: JR_JBPE-13-3_006
منتشر شده در در سال 1402
مشخصات نویسندگان مقاله:

Mohammad Mehdi Movahedi - Department of Medical Physics and Biomedical Engineering, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran
Mohamadreza Shakerpour - School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran
Shahrokh Mousavi - Student Research Committee, Shiraz University of Medical Sciences, Shiraz, Iran
Ahmad Nori - Novin Iran Specialized Clinic, Shiraz, Iran
Seyyed Hesam Mousavian Dehkordi - Faculty of Electrical Engineering, Shiraz University of Technology, Shiraz, Iran
Hossein Parsaei - Department of Medical Physics and Biomedical Engineering, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran

خلاصه مقاله:
Background: Phonocardiogram (PCG) signal provides valuable information for diagnosing heart diseases. However, its applications in quantitative analyses of heart function are limited because the interpretation of this signal is difficult. A key step in quantitative PCG is the identification of the first and second sounds (S۱ and S۲) in this signal.Objective: This study aims to develop a hardware-software system for synchronized acquisition of two signals electrocardiogram (ECG) and PCG and to segment the recorded PCG signal via the information provided in the acquired ECG signal.Material and Methods: In this analytical study, we developed a hardware-software system for real-time identification of the first and second heart sounds in the PCG signal. A portable device to capture synchronized ECG and PCG signals was developed. Wavelet de-noising technique was used to remove noise from the signal. Finally, by fusing the information provided by the ECG signal (R-peaks and T-end) into a hidden Markov model (HMM), the first and second heart sounds were identified in the PCG signal.Results: ECG and PCG signals from ۱۵ healthy adults were acquired and analyzed using the developed system. The average accuracy of the system in correctly detecting the heart sounds was ۹۵.۶% for S۱ and ۹۳.۴% for S۲.  Conclusion: The presented system is cost-effective, user-friendly, and accurate in identifying S۱ and S۲ in PCG signals. Therefore, it might be effective in quantitative PCG and diagnosing heart diseases.

کلمات کلیدی:
Electrocardiogram, Electrocardiography, Heart Sounds, Markov Chains, Phonocardiography, PCG Segmentation