Optimal planning and design of waste-to-energy plant for aquaculture systems

  • سال انتشار: 1402
  • محل انتشار: مجله مدیریت و مهندسی بهداشت محیط، دوره: 10، شماره: 4
  • کد COI اختصاصی: JR_EHEM-10-4_005
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 172
دانلود فایل این مقاله

نویسندگان

Desmond Eseoghene Ighravwe

Corresponding author: Department of Mechanical Engineering, Bells University of Technology, Ota, Nigeria

Akpevweoghene Solomon Abijah

University of Limerick, Castletroy, Limerick, V۹۴ T۹PX, Ireland

Daniel Osezua Aikhuele

Department of Mechanical Engineering, University of Port-Harcourt, Nigeria

Sunday Thomas Ajayi

Department of Mechanical Engineering, Bells University of Technology, Ota, Nigeria

Johnson Adeleke Adeyiga

Department of Computer Science and Information Technology, Bells University of Technology, Ota, Nigeria

چکیده

Background: Several aquaculture industries in underdeveloped nations use fossil fuel-powered generators to produce electricity. This pattern has raised greenhouse gas emissions as well as the price of aquaculture products. Methods: To address this issue, this study contains a bi-objective model that optimizes the parametric settings of waste-to-energy (WTE) plants for aquaculture firms: Levelized cost of energy and power expenses for reverse logistics. The best values for these objectives were created using a genetic algorithm and goal programming. Results: Four planning periods were taken into account during implementation, and actual data were gathered from a Nigerian aquaculture company. The electricity costs from biodiesel ranged from N۰.۷۵۴۱ per kW to N۰.۷۶۲۸ per kW, respectively. Reverse logistics has energy costs ranging from N۶ ۳۲۹ ۴۹۲.۱۰ to N۷ ۱۲۱ ۰۱۵.۵۳. The proposed model produced average values for several WTE parametric parameters, including a ۱.۶۹ million kg hydrogen gas, a ۵۹.۱۶% hydrogen gas compression efficiency, and an ۸۳.۳۹% electricity conversion efficiency. Furthermore, the system had logistics’ minimum and maximum fractions of ۰.۱۸% and ۲۱%, respectively. Conclusion: Our findings demonstrated how WTE parametric parameters impact the aquaculture industry’s electrical power unit.

کلیدواژه ها

Algorithm, Aquaculture, Electricity, Hydrogen, Nigeria

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.