Combining Dispersive Solid Phase Extraction-dispersive Liquid-liquid Microextraction Using Walnut Green Husk as an Efficient Adsorbent for the Extraction of Lead and Cadmium Ions from Oil Samples Prior to Flame Atomic Absorption Spectrometry

  • سال انتشار: 1403
  • محل انتشار: مجله تحقیقات شیمی تجزیه و تجزیه زیستی، دوره: 11، شماره: 1
  • کد COI اختصاصی: JR_ANALCH-11-1_005
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 99
دانلود فایل این مقاله

نویسندگان

Aysan Changhizi

Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran

Saeed Mohammad Sorouraddin

Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran

Mir Ali Farajzadeh

Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran. Engineering Faculty, Near East University, ۹۹۱۳۸ Nicosia, North Cyprus, Mersin ۱۰, Turkey

Ali Akbar Fathi

Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran

چکیده

In this work, walnut green husk has been used as a simple, cheap, biodegradable, and efficient adsorbent in dispersive solid phase extraction of Cd (II) and Pb (II) ions from some oil samples including edible, fish oil, and butter. In the next step, a dispersive liquid-liquid microextraction method was used to enrich the extracted analytes before their analysis with flame atomic absorption spectrometry. For this purpose, the adsorbent was obtained from agricultural wastes, dried in an isolated environment at ambient temperature, and mechanically ground to obtain a homogeneous powder. The parameters affecting the efficiency of the method were optimized. Low detection limits (۰.۱۲ and ۰.۳۲ µg L-۱ for Cd (II) and Pb (II), respectively), low relative standard deviations (۳.۸% and ۴.۲% for Cd (II) and Pb (II), respectively) and determination coefficients close to ۱ (۰.۹۹۱ and ۰.۹۹۵ for Cd (II) and Pb (II), respectively) were achieved. Also, the extraction recoveries for the target analytes were ۸۹ and ۹۶% for Cd (II) and Pb (II), respectively.

کلیدواژه ها

Heavy metal, Walnut green husk, Dispersive solid phase extraction, Dispersive liquid-liquid microextraction, Flame atomic absorption spectrometry, Oil