Impact of region of interest size and location in Gafchromic film dosimetry

سال انتشار: 1397
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 101

نسخه کامل این مقاله ارائه نشده است و در دسترس نمی باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_IJMP-15-0_409

تاریخ نمایه سازی: 29 آذر 1402

چکیده مقاله:

Introduction: Accurate film dosimetry requires careful consideration of sources of uncertainty. Some of the sources of uncertainty are dependent on the size and location of region of interest (ROI), especially in small fields. Avoiding the penumbra is often a reason for using a small ROI. In contrast, choosing very small ROIs may increase uncertainty due to the reduction of the sampling data. Using a dose profile as flat as possible for the ROI becomes more significant in small fields in which the flatness of profile is greatly affected by the penumbra. This study aims to evaluate dependency of measured dose on size and location of region of interest (ROI) in Gafchromic EBT۳ film for small field dosimetry. Materials and Methods: Gafchromic EBT۳ films were irradiated using the ۶MV beam from a linear accelerator at ۱۰ cm depth (۱۰۰ cm SSD) of a solid water phantom for a range of field sizes of ۶×۶ to ۱۰۰×۱۰۰ mm۲. For scanning, ۴۸ bits RGB mode with a spatial resolution of ۷۲ dpi was used. The red channel of ImageJ software was used for evaluation. The appropriate location of ROIs were found by two methods. First, the ROI was visually placed at the center of image. Second, the profile of pixel value versus distance was plotted and the center of profile was used. Each scanned film was read using both methods and for three ROI sizes (۱, ۲, and ۴ mm). In every scan, the film was re-positioned in the center of scanner. This uncertainty was compared with scan-to-scan variability when using piece of glass on top of the film. A plastic scintillator, Exradin W۱, was used as a reference dosimeter. To obtain doses from W۱ scintillator, a calibrated ion chamber with the same setup as W۱ was used. Results: Comparing the three ROI sizes using both methods showed that there is less than ۲% difference from reference in output factor measurements for field sizes larger or equal to ۱۰×۱۰ mm۲. For field sizes of ۱۵×۱۵ and ۱۰×۱۰ mm۲, the smaller mean percentage differences were observed in profiled-ROI (۴×۴ mm۲) and centered-ROI (۴×۴ mm۲). For the field sizes of ۸×۸ and ۶×۶ mm۲, the profiled-ROI (۲×۲ mm۲) had smallest mean percentage difference, which was ۰.۸۸%. The scan to scan variability was less than ۰.۳۱%. Conclusion: The ROI size of ۴×۴ mm۲ is appropriate for dose measurements in field sizes of ۱۰۰×۱۰۰ mm۲ to ۱۰×۱۰ mm۲, regardless of the method of finding location of ROI. In field sizes smaller than ۱۰×۱۰ mm۲, finding location of the ROI by profile of pixel values increases the accuracy of measurement, and ROI size of ۲×۲ mm۲ has the smallest difference from the reference dose measurements.

نویسندگان

Neda Gholizadeh Sendani

Department of Medical Radiation Engineering, University of Isfahan, Isfahan, Iran

Alireza Karimian

Department of Radiation Oncology, University of Minnesota, Minneapolis, Minnesota, USA

S. Rabie Mahdavi

Department of Biomedical Engineering, University of Isfahan, Isfahan, Iran

Iraj Jabari

Radiation Biology Research Center and Department of Radiation Oncology, University of Minnesota, Minneapolis, Minnesota, USA

Clara Ferreira

Department of Radiation Oncology, University of Minnesota, Minneapolis, Minnesota, USA

Parham Alaei

Department of Medical Radiation Engineering, University of Isfahan, Isfahan, Iran